TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 32 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.54 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Fire Resistance:
- 850°C IEC 60695-2-1
- Protective Treatment:
- THIEC 60068-2-30
- [Icw] Rated Short-Time Withstand Current:
- 640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Coil Technology:
- without built-in suppressor module
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Pole Contact Composition:
- 4 NO
- Overvoltage Category:
- III
- Heat Dissipation:
- 4-5 W at 50/60 Hz
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Control Circuit Type:
- AC 50/60 Hz
- Protective Cover:
- with
- Toxic Heavy Metal Free:
- Yes
- Contactor Application:
- resistive load
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Circularity Profile:
- ENVEOLI1503009EN
- Height:
- 122 mm
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- [Uc] Control Circuit Voltage:
- 32 V AC 50/60 Hz
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Pvc Free:
- Yes
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Depth:
- 120 mm
- Net Weight:
- 1.15 kg
- Signaling Circuit Frequency:
- 25...400 Hz
- Device Short Name:
- LC1D
- Flame Retardance:
- V1 conforming to UL 94
- Weight:
- 1.15 kg
- Mounting Support:
- plate || rail
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Width:
- 70 mm
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
- Range:
- TeSys || TeSys Deca
- Mechanical Durability:
- 6 Mcycles
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Power Dissipation Per Pole:
- 10.2 W AC-1
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
- Rated Breaking Capacity:
- 1000 A at 440 V for power circuit conforming to IEC 60947
- Product Certifications:
- LROS (Lloyds register of shipping) || CCC || GL || DNV || CSA || GOST || UL || BV || RINA
- Sustainable Offer Status:
- Green Premium product
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Product Or Component Type:
- contactor