[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Product Or Component Type:
contactor
Mercury Free:
Yes
Flame Retardance:
V1 conforming to UL 94
Range:
TeSys || TeSys Deca
Signaling Circuit Frequency:
25...400 Hz
Rohs Exemption Information:
Yes
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
Auxiliary Contact Composition:
1 NO + 1 NC
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Sustainable Offer Status:
Green Premium product
Height:
122 mm
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Warranty:
18 months
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Toxic Heavy Metal Free:
Yes
Minimum Switching Current:
5 mA for Signaling circuit
Operating Time:
4...19 ms opening || 12...26 ms closing
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Contactor Application:
resistive load
Electrical Durability:
1.4 Mcycles 80 A AC-1 <= 440 V
Pole Contact Composition:
4 NO
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Country of Origin:
France
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || power circuit 5 N.m screw clamp terminals 1-25 mm² hex
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Voltage:
17 V for Signaling circuit
Utilisation Category:
AC-1
Net Weight:
1.15 kg
Product Certifications:
RINA || CSA || LROS (Lloyds register of shipping) || CCC || DNV || UL || GOST || GL || BV
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Eu Rohs Directive:
Compliant
Reach Free Of Svhc:
Yes
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Pollution Degree:
3
Environmental Disclosure:
ENVPEP1503009EN
Device Short Name:
LC1D
Compatibility Code:
LC1D
Insulation Resistance:
> 10 MOhm for Signaling circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Mounting Support:
rail || plate
$540.96

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 115 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.54 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.