Schneider Electric LC1DT80AFE7 IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 115VAC 50/60Hz coil, open style
Schneider Electric
$540.96
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 115 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.54 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Product Or Component Type:
- contactor
- Mercury Free:
- Yes
- Flame Retardance:
- V1 conforming to UL 94
- Range:
- TeSys || TeSys Deca
- Signaling Circuit Frequency:
- 25...400 Hz
- Rohs Exemption Information:
- Yes
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Sustainable Offer Status:
- Green Premium product
- Height:
- 122 mm
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Warranty:
- 18 months
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Toxic Heavy Metal Free:
- Yes
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Contactor Application:
- resistive load
- Electrical Durability:
- 1.4 Mcycles 80 A AC-1 <= 440 V
- Pole Contact Composition:
- 4 NO
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Country of Origin:
- France
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || power circuit 5 N.m screw clamp terminals 1-25 mm² hex
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Utilisation Category:
- AC-1
- Net Weight:
- 1.15 kg
- Product Certifications:
- RINA || CSA || LROS (Lloyds register of shipping) || CCC || DNV || UL || GOST || GL || BV
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
- Eu Rohs Directive:
- Compliant
- Reach Free Of Svhc:
- Yes
- Rated Breaking Capacity:
- 1000 A at 440 V for power circuit conforming to IEC 60947
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Pollution Degree:
- 3
- Environmental Disclosure:
- ENVPEP1503009EN
- Device Short Name:
- LC1D
- Compatibility Code:
- LC1D
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Mounting Support:
- rail || plate