Schneider Electric

Schneider Electric LC1DT80AJD IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 12VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT80AJD
MPN:
LC1DT80AJD
Condition:
New
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Uc] Control Circuit Voltage:
12 V DC
Reach Free Of Svhc:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Compatibility Code:
LC1D
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Product Certifications:
CSA || UL || DNV || CCC || BV || RINA || GL || GOST || LROS (Lloyds register of shipping)
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Depth:
120 mm
Product Or Component Type:
contactor
Ip Degree Of Protection:
IP20 front face IEC 60529
Electrical Durability:
0.5 Mcycles 80 A AC-1 <= 440 V
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Utilisation Category:
AC-1
Poles Description:
4P
Time Constant:
34 ms
Device Short Name:
LC1D
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Contactor Application:
resistive load
Maximum Operating Rate:
3600 cyc/h 60°C
Fire Resistance:
850°C IEC 60695-2-1
Pole Contact Composition:
4 NO
Signaling Circuit Frequency:
25...400 Hz
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Country of Origin:
France
Protective Cover:
with
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Voltage:
17 V for Signaling circuit
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
Operating Time:
50±15 % ms closing || 16...24 ms opening
Pollution Degree:
3
Circularity Profile:
ENVEOLI1503009EN
Power Dissipation Per Pole:
10.2 W AC-1
Auxiliary Contact Composition:
1 NO + 1 NC
Eu Rohs Directive:
Compliant
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Weight:
1.225 kg
Flame Retardance:
V1 conforming to UL 94
Sustainable Offer Status:
Green Premium product
Range Of Product:
TeSys Deca
Protective Treatment:
THIEC 60068-2-30
Mercury Free:
Yes
Net Weight:
1.225 kg
Height:
122 mm
Overvoltage Category:
III
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Minimum Switching Current:
5 mA for Signaling circuit
$535.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 12 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.70 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose