Schneider Electric

Schneider Electric LC1DT80AM7 IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 220VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT80AM7
MPN:
LC1DT80AM7
Condition:
New
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Mercury Free:
Yes
Circularity Profile:
ENVEOLI1503009EN
Toxic Heavy Metal Free:
Yes
Eu Rohs Directive:
Compliant
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || power circuit 5 N.m screw clamp terminals 1-25 mm² hex
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Operating Time:
4...19 ms opening || 12...26 ms closing
Utilisation Category:
AC-1
Poles Description:
4P
Country of Origin:
Indonesia
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Mounting Support:
plate || rail
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Environmental Disclosure:
ENVPEP1503009EN
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Reach Free Of Svhc:
Yes
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Net Weight:
1.15 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Heat Dissipation:
4-5 W at 50/60 Hz
Range Of Product:
TeSys Deca
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
Contactor Application:
resistive load
Minimum Switching Voltage:
17 V for Signaling circuit
Compatibility Code:
LC1D
Auxiliary Contact Composition:
1 NO + 1 NC
Depth:
120 mm
Protective Treatment:
THIEC 60068-2-30
Ip Degree Of Protection:
IP20 front face IEC 60529
[Uc] Control Circuit Voltage:
220 V AC 50/60 Hz
Pollution Degree:
3
Pole Contact Composition:
4 NO
Flame Retardance:
V1 conforming to UL 94
Warranty:
18 months
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Device Short Name:
LC1D
Average Impedance:
1.6 mOhm - Ith 80 A 50 Hz for power circuit
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Signaling Circuit Frequency:
25...400 Hz
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Overvoltage Category:
III
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Protective Cover:
with
$540.96

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.54 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose