Schneider Electric LC1DT80AN7 IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 415VAC 50/60Hz coil, open style
Schneider Electric
$540.96
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 415 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.54 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Pollution Degree:
- 3
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
- Protective Treatment:
- THIEC 60068-2-30
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Range Of Product:
- TeSys Deca
- Pole Contact Composition:
- 4 NO
- Device Short Name:
- LC1D
- Mechanical Durability:
- 6 Mcycles
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Pvc Free:
- Yes
- Protective Cover:
- with
- Utilisation Category:
- AC-1
- Product Certifications:
- GOST || BV || CSA || LROS (Lloyds register of shipping) || CCC || UL || DNV || GL || RINA
- Environmental Disclosure:
- ENVPEP1503009EN
- Circularity Profile:
- ENVEOLI1503009EN
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Rated Breaking Capacity:
- 1000 A at 440 V for power circuit conforming to IEC 60947
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || power circuit 5 N.m screw clamp terminals 1-25 mm² hex
- Rohs Exemption Information:
- Yes
- Electrical Durability:
- 1.4 Mcycles 80 A AC-1 <= 440 V
- Height:
- 122 mm
- Sustainable Offer Status:
- Green Premium product
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Weight:
- 1.15 kg
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Coil Technology:
- without built-in suppressor module
- Contactor Application:
- resistive load
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Net Weight:
- 1.15 kg
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Width:
- 70 mm
- Mounting Support:
- rail || plate
- [Uc] Control Circuit Voltage:
- 415 V AC 50/60 Hz
- Warranty:
- 18 months
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Average Impedance:
- 1.6 mOhm - Ith 80 A 50 Hz for power circuit