Schneider Electric

Schneider Electric LC1G115LSEA Contactor, high power, TeSys Giga, advanced version, 3 pole/NO, AC-3 <=440V 115A, 200-500VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G115LSEA
MPN:
LC1G115LSEA
Condition:
New
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Halogen Content Performance:
Halogen free plastic parts product
[Ie] Rated Operational Current:
250 A (at <40°C) at <= 1000 V AC-1 || 115 A (at <60°C) at <= 440 V AC-3
Overvoltage Category:
III
Compatibility Code:
LC1G
Pole Contact Composition:
3 NO
Pvc Free:
Yes
Coil Technology:
built-in bidirectional peak limiting
Mercury Free:
Yes
Connection Pitch:
35 mm
Device Short Name:
LC1G
Ambient Air Temperature For Storage:
-60-80°C
Auxiliary Contact Composition:
1 NO + 1 NC
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Weight:
4.1 kg
Eu Rohs Directive:
Compliant with Exemptions
Hold-In Power Consumption In Va:
13.0-13.0 VA
Environmental Disclosure:
ENVPEP2105013
Product Or Component Type:
contactor
Rated Breaking Capacity:
1040 A at 440 V
China Rohs Regulation:
X
Circularity Profile:
ENVEOLI2105013
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
Protective Treatment:
TH
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Inrush Power In W:
215 W
Hold-In Power Consumption In W:
8.0-8.0 W
Maximum Horse Power Rating:
30 hp at 200/208 V 60 Hz || 40 hp at 230/240 V 60 Hz || 75 hp at 460/480 V 60 Hz || 100 hp at 575/600 V 60 Hz
Motor Power Kw:
30 kW at 230 V AC 50/60 Hz (AC-3e) || 55 kW at 400 V AC 50/60 Hz (AC-3e) || 55 kW at 415 V AC 50/60 Hz (AC-3e) || 75 kW at 440 V AC 50/60 Hz (AC-3e) || 75 kW at 500 V AC 50/60 Hz (AC-3e) || 75 kW at 690 V AC 50/60 Hz (AC-3e) || 30 kW at 230 V AC 50/6
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Mechanical Durability:
8 Mcycles
Color:
dark grey
Net Weight:
4.1 kg
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Depth:
193 mm
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Power Dissipation Per Pole:
10 W AC-1 - Ith 250 A || 3 W AC-3 - Ith 115 A
Contactor Application:
power switching || motor control
Country of Origin:
China
Range:
TeSys
Range Of Product:
TeSys Giga
$750.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 115A 75kW@440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose