Schneider Electric

Schneider Electric LC1G150BEEA Contactor, high power, TeSys Giga, advanced version, AC-3, <= 440V, 150A, 3 pole/NO, 24-48VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G150BEEA
MPN:
LC1G150BEEA
Condition:
New
Compatibility Code:
LC1G
Protective Treatment:
TH
Net Weight:
4.1 kg
Coil Technology:
built-in bidirectional peak limiting
Range:
TeSys
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
[Ith] Conventional Free Air Thermal Current:
275 A (at 40°C)
Mechanical Durability:
8 Mcycles
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Weight:
4.1 kg
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Eu Rohs Directive:
Compliant with Exemptions
Hold-In Power Consumption In W:
5.7-5.7 W
Width:
108 mm
Height:
255 mm
Ambient Air Temperature For Storage:
-60-80°C
Rated Breaking Capacity:
1280 A at 440 V
Ambient Air Temperature For Operation:
-25-60°C
[Ie] Rated Operational Current:
275 A (at <40°C) at <= 1000 V AC-1 || 150 A (at <60°C) at <= 440 V AC-3
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Pole Contact Composition:
3 NO
Hold-In Power Consumption In Va:
10-10 VA
[Icw] Rated Short-Time Withstand Current:
1.2 kA - 10 s || 0.7 kA - 30 s || 0.6 kA - 1 min || 0.45 kA - 3 min || 0.35 kA - 10 min
Environmental Disclosure:
ENVPEP2105013
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Tightening Torque:
18 N.m
Connection Pitch:
35 mm
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
China Rohs Regulation:
X
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Maximum Horse Power Rating:
40 hp at 200/208 V 60 Hz || 50 hp at 230/240 V 60 Hz || 100 hp at 460/480 V 60 Hz || 125 hp at 575/600 V 60 Hz
Average Impedance:
0.00018 Ohm
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Circularity Profile:
ENVEOLI2105013
[Uc] Control Circuit Voltage:
24...48 V AC 50/60 Hz || 24...48 V DC
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Motor Power Kw:
37 kW at 230 V AC 50/60 Hz (AC-3e) || 75 kW at 400 V AC 50/60 Hz (AC-3e) || 75 kW at 415 V AC 50/60 Hz (AC-3e) || 90 kW at 440 V AC 50/60 Hz (AC-3e) || 90 kW at 500 V AC 50/60 Hz (AC-3e) || 90 kW at 690 V AC 50/60 Hz (AC-3e) || 75 kW at 1000 V AC 50/
Contactor Application:
power switching || motor control
Associated Fuse Rating:
160 A aM at <= 440 V for motor || 160 A aM at <= 690 V for motor || 315 A gG at <= 690 V
Irms Rated Making Capacity:
1890 A at 440 V
Inrush Power In W:
220 W
Pvc Free:
Yes
Device Short Name:
LC1G
Poles Description:
3P
Auxiliary Contact Composition:
1 NO + 1 NC
Country of Origin:
China
Product Or Component Type:
contactor
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
$850.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 150A 90kW@440V. It provides a 24-48V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose