Schneider Electric

Schneider Electric LC1G150LSEN Contactor, high power, TeSys Giga, 3P(3NO), AC-3, <=440V 150A, standard version, 200-500V AC/DC wide band coil

(No reviews yet) Write a Review
SKU:
LC1G150LSEN
MPN:
LC1G150LSEN
Condition:
New
Inrush Power In W:
215 W
Depth:
193 mm
Environmental Disclosure:
ENVPEP2105013
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Color:
dark grey
Ambient Air Temperature For Operation:
-25-60°C
Irms Rated Making Capacity:
1890 A at 440 V
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Operating Time:
40...70 ms closing || 15...50 ms opening
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Connection Pitch:
35 mm
Height:
193 mm
Power Dissipation Per Pole:
10 W AC-1 - Ith 275 A || 5 W AC-3 - Ith 150 A
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
[Icw] Rated Short-Time Withstand Current:
1.2 kA - 10 s || 0.7 kA - 30 s || 0.6 kA - 1 min || 0.45 kA - 3 min || 0.35 kA - 10 min
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
[Ui] Rated Insulation Voltage:
1000 V
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
Rated Breaking Capacity:
1280 A at 440 V
Protective Treatment:
TH
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Motor Power Kw:
37 kW at 230 V AC 50/60 Hz (AC-3e) || 75 kW at 400 V AC 50/60 Hz (AC-3e) || 75 kW at 415 V AC 50/60 Hz (AC-3e) || 90 kW at 440 V AC 50/60 Hz (AC-3e) || 90 kW at 500 V AC 50/60 Hz (AC-3e) || 90 kW at 690 V AC 50/60 Hz (AC-3e) || 75 kW at 1000 V AC 50/
Maximum Horse Power Rating:
40 hp at 200/208 V 60 Hz || 50 hp at 230/240 V 60 Hz || 100 hp at 460/480 V 60 Hz || 125 hp at 575/600 V 60 Hz
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Associated Fuse Rating:
160 A aM at <= 440 V for motor || 160 A aM at <= 690 V for motor || 315 A gG at <= 690 V
Poles Description:
3P
Product Or Component Type:
contactor
Coil Technology:
built-in bidirectional peak limiting
Eu Rohs Directive:
Compliant with Exemptions
Hold-In Power Consumption In W:
8-8 W
Average Impedance:
0.00018 Ohm
Compatibility Code:
LC1G
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Country of Origin:
China
Tightening Torque:
18 N.m
Range Of Product:
TeSys Giga
Width:
108 mm
Weight:
3.6 kg
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Inrush Power In Va:
295-295 VA
Mechanical Durability:
8 Mcycles
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Auxiliary Contact Composition:
1 NO + 1 NC
Mounting Support:
plate
$850.00