Schneider Electric

Schneider Electric LC1G1854BEEA Contactor, high power, TeSys Giga, advanced version, AC-1, <= 440V, 305A, 4 pole/NO, 24-48VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G1854BEEA
MPN:
LC1G1854BEEA
Condition:
New
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Sustainable Offer Status:
Green Premium product
Average Impedance:
0.00017 Ohm
[Ie] Rated Operational Current:
185 A (at <60°C) at <= 440 V AC-3 || 305 A (at <40°C) at <= 1000 V AC-1
Hold-In Power Consumption In W:
5.7-5.7 W
Connection Pitch:
35 mm
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Depth:
193 mm
[Icw] Rated Short-Time Withstand Current:
1.5 kA - 10 s || 0.92 kA - 30 s || 0.74 kA - 1 min || 0.5 kA - 3 min || 0.4 kA - 10 min
Contactor Application:
power switching
[Ith] Conventional Free Air Thermal Current:
250 A (at 40°C)
Auxiliary Contact Composition:
1 NO + 1 NC
Mounting Support:
plate
Tightening Torque:
18 N.m
Ambient Air Temperature For Operation:
-25-60°C
Pvc Free:
Yes
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
Associated Fuse Rating:
200 A aM at <= 440 V for motor || 160 A aM at <= 690 V for motor || 315 A gG at <= 690 V
Width:
143 mm
Circularity Profile:
ENVEOLI2105013
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Device Short Name:
LC1G
[Ui] Rated Insulation Voltage:
1000 V
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Rated Breaking Capacity:
1610 A at 440 V
Product Or Component Type:
contactor
Poles Description:
4P
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Inrush Power In Va:
290-290 VA
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
China Rohs Regulation:
X
Coil Technology:
built-in bidirectional peak limiting
Pole Contact Composition:
4 NO
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
Power Dissipation Per Pole:
20 W AC-1 - Ith 305 A || 6 W AC-3 - Ith 185 A
Hold-In Power Consumption In Va:
10-10 VA
Overvoltage Category:
III
Mechanical Durability:
8 Mcycles
Inrush Power In W:
220 W
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Range:
TeSys
Irms Rated Making Capacity:
1560 A at 440 V
Weight:
5.1 kg
$1,280.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 305A @440V. It provides a 24-48V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 143mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose