Schneider Electric

Schneider Electric LC1G1854EHEN Contactor, high power, TeSys Giga, standard version, 4 pole/NO, AC-1 <=440V 305A, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G1854EHEN
MPN:
LC1G1854EHEN
Condition:
New
Range:
TeSys
Tightening Torque:
18 N.m
Mercury Free:
Yes
China Rohs Regulation:
X
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Circularity Profile:
ENVEOLI2105013
Hold-In Power Consumption In W:
7.8-7.8 W
Protective Treatment:
TH
Country of Origin:
China
Pvc Free:
Yes
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
Hold-In Power Consumption In Va:
18.7-18.7 VA
Associated Fuse Rating:
200 A aM at <= 440 V for motor || 160 A aM at <= 690 V for motor || 315 A gG at <= 690 V
Height:
193 mm
[Ith] Conventional Free Air Thermal Current:
305 A (at 40°C)
[Icw] Rated Short-Time Withstand Current:
1.5 kA - 10 s || 0.92 kA - 30 s || 0.74 kA - 1 min || 0.5 kA - 3 min || 0.4 kA - 10 min
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Halogen Content Performance:
Halogen free plastic parts product
Overvoltage Category:
III
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Power Dissipation Per Pole:
20 W AC-1 - Ith 305 A || 6 W AC-3 - Ith 185 A
Eu Rohs Directive:
Compliant with Exemptions
Sustainable Offer Status:
Green Premium product
Device Short Name:
LC1G
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Ambient Air Temperature For Operation:
-25-60°C
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² - c
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Mounting Support:
plate
Inrush Power In Va:
640-640 VA
Net Weight:
4.4 kg
Pole Contact Composition:
4 NO
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
Compatibility Code:
LC1G
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Range Of Product:
TeSys Giga
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Average Impedance:
0.00017 Ohm
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
Depth:
193 mm
Inrush Power In W:
445 W
Coil Technology:
built-in bidirectional peak limiting
Poles Description:
4P
Color:
dark grey
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
[Ui] Rated Insulation Voltage:
1000 V
$1,110.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 305A @440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 143mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose