Schneider Electric

Schneider Electric LC1G1854LSEA Contactor, high power, TeSys Giga, advanced version, 4 pole/NO, AC-1 <=440V 305A, 200-500VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G1854LSEA
MPN:
LC1G1854LSEA
Condition:
New
Product Or Component Type:
contactor
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Range Of Product:
TeSys Giga
Overvoltage Category:
III
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Mechanical Durability:
8 Mcycles
Sustainable Offer Status:
Green Premium product
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
[Ith] Conventional Free Air Thermal Current:
305 A (at 40°C)
Depth:
193 mm
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Protective Treatment:
TH
Ambient Air Temperature For Storage:
-60-80°C
Weight:
5.1 kg
Tightening Torque:
18 N.m
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-25-60°C
[Ie] Rated Operational Current:
185 A (at <60°C) at <= 440 V AC-3 || 305 A (at <40°C) at <= 1000 V AC-1
Inrush Power In Va:
295-295 VA
Pole Contact Composition:
4 NO
Range:
TeSys
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Average Impedance:
0.00017 Ohm
Country of Origin:
China
Inrush Power In W:
215 W
Poles Description:
4P
Hold-In Power Consumption In Va:
13.0-13.0 VA
Width:
143 mm
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Halogen Content Performance:
Halogen free plastic parts product
Mounting Support:
plate
China Rohs Regulation:
X
Rohs Exemption Information:
Yes
Power Dissipation Per Pole:
20 W AC-1 - Ith 305 A || 6 W AC-3 - Ith 185 A
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Operating Time:
40...70 ms closing || 15...50 ms opening
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Coil Technology:
built-in bidirectional peak limiting
Contactor Application:
power switching
Irms Rated Making Capacity:
2310 A at 440 V
Device Short Name:
LC1G
Net Weight:
5.1 kg
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
[Ui] Rated Insulation Voltage:
1000 V
$1,280.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 305A @440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 143mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose