Schneider Electric

Schneider Electric LC1G185BEEA Contactor, high power, TeSys Giga, advanced version, AC-3, <= 440V, 185A, 3 pole/NO, 24-48VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G185BEEA
MPN:
LC1G185BEEA
Condition:
New
Hold-In Power Consumption In W:
5.7-5.7 W
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Color:
dark grey
Protective Treatment:
TH
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Sustainable Offer Status:
Green Premium product
Width:
108 mm
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
China Rohs Regulation:
X
Device Short Name:
LC1G
Environmental Disclosure:
ENVPEP2105013
Compatibility Code:
LC1G
Mounting Support:
plate
Range:
TeSys
Rohs Exemption Information:
Yes
Ambient Air Temperature For Storage:
-60-80°C
[Uc] Control Circuit Voltage:
24...48 V AC 50/60 Hz || 24...48 V DC
Halogen Content Performance:
Halogen free plastic parts product
[Ith] Conventional Free Air Thermal Current:
305 A (at 40°C)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Mechanical Durability:
8 Mcycles
Mercury Free:
Yes
Contactor Application:
power switching || motor control
Net Weight:
4.1 kg
Eu Rohs Directive:
Compliant with Exemptions
Motor Power Kw:
55 kW at 230 V AC 50/60 Hz (AC-3e) || 90 kW at 400 V AC 50/60 Hz (AC-3e) || 90 kW at 415 V AC 50/60 Hz (AC-3e) || 110 kW at 440 V AC 50/60 Hz (AC-3e) || 110 kW at 500 V AC 50/60 Hz (AC-3e) || 110 kW at 690 V AC 50/60 Hz (AC-3e) || 75 kW at 1000 V AC
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Power Dissipation Per Pole:
20 W AC-1 - Ith 305 A || 6 W AC-3 - Ith 185 A
Overvoltage Category:
III
Inrush Power In Va:
290-290 VA
[Icw] Rated Short-Time Withstand Current:
1.5 kA - 10 s || 0.92 kA - 30 s || 0.74 kA - 1 min || 0.5 kA - 3 min || 0.4 kA - 10 min
Country of Origin:
China
Associated Fuse Rating:
200 A aM at <= 440 V for motor || 160 A aM at <= 690 V for motor || 315 A gG at <= 690 V
[Ie] Rated Operational Current:
305 A (at <40°C) at <= 1000 V AC-1 || 185 A (at <60°C) at <= 440 V AC-3
Hold-In Power Consumption In Va:
10-10 VA
Irms Rated Making Capacity:
2310 A at 440 V
Connection Pitch:
35 mm
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
Circularity Profile:
ENVEOLI2105013
Rated Breaking Capacity:
1610 A at 440 V
Pvc Free:
Yes
[Ui] Rated Insulation Voltage:
1000 V
$990.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 185A 110kW@440V. It provides a 24-48V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose