Schneider Electric

Schneider Electric LC1G185LSEA Contactor, high power, TeSys Giga, advanced version, 3 pole/NO, AC-3 <=440V 185A, 200-500VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G185LSEA
MPN:
LC1G185LSEA
Condition:
New
Pvc Free:
Yes
Net Weight:
4.1 kg
Mechanical Durability:
8 Mcycles
[Icw] Rated Short-Time Withstand Current:
1.5 kA - 10 s || 0.92 kA - 30 s || 0.74 kA - 1 min || 0.5 kA - 3 min || 0.4 kA - 10 min
Motor Power Kw:
55 kW at 230 V AC 50/60 Hz (AC-3e) || 90 kW at 400 V AC 50/60 Hz (AC-3e) || 90 kW at 415 V AC 50/60 Hz (AC-3e) || 110 kW at 440 V AC 50/60 Hz (AC-3e) || 110 kW at 500 V AC 50/60 Hz (AC-3e) || 110 kW at 690 V AC 50/60 Hz (AC-3e) || 75 kW at 1000 V AC
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Protective Treatment:
TH
Country of Origin:
China
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Inrush Power In W:
215 W
Circularity Profile:
ENVEOLI2105013
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
contactor
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Rated Breaking Capacity:
1610 A at 440 V
China Rohs Regulation:
X
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Average Impedance:
0.00017 Ohm
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
[Ie] Rated Operational Current:
305 A (at <40°C) at <= 1000 V AC-1 || 185 A (at <60°C) at <= 440 V AC-3
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Hold-In Power Consumption In Va:
13.0-13.0 VA
Maximum Horse Power Rating:
50 hp at 200/208 V 60 Hz || 60 hp at 230/240 V 60 Hz || 125 hp at 460/480 V 60 Hz || 150 hp at 575/600 V 60 Hz
Operating Time:
40...70 ms closing || 15...50 ms opening
Contactor Application:
power switching || motor control
Power Dissipation Per Pole:
20 W AC-1 - Ith 305 A || 6 W AC-3 - Ith 185 A
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP2105013
Rohs Exemption Information:
Yes
Device Short Name:
LC1G
Color:
dark grey
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ui] Rated Insulation Voltage:
1000 V
[Uimp] Rated Impulse Withstand Voltage:
8 kV
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Pole Contact Composition:
3 NO
Eu Rohs Directive:
Compliant with Exemptions
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
Ambient Air Temperature For Storage:
-60-80°C
Sustainable Offer Status:
Green Premium product
Auxiliary Contact Composition:
1 NO + 1 NC
Connection Pitch:
35 mm
Weight:
4.1 kg
$990.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 185A 110kW@440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose