Schneider Electric LC1G185LSEN Contactor, high power, TeSys Giga, 3P(3NO), AC-3, <=440V 185A, standard version, 200-500V AC/DC wide band coil
Schneider Electric
$990.00
Contactor, high power, TeSys Giga, 3P(3NO), AC-3, <=440V 185A, standard version, 200-500V AC/DC wide band coil
- Ip Degree Of Protection:
- IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
- Control Circuit Voltage Limits:
- operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
- Color:
- dark grey
- Hold-In Power Consumption In W:
- 8-8 W
- Irms Rated Making Capacity:
- 2310 A at 440 V
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
- Connection Pitch:
- 35 mm
- Height:
- 193 mm
- Maximum Operating Rate:
- 600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
- Hold-In Power Consumption In Va:
- 13-13 VA
- Associated Fuse Rating:
- 200 A aM at <= 440 V for motor || 160 A aM at <= 690 V for motor || 315 A gG at <= 690 V
- Environmental Disclosure:
- ENVPEP2105013
- Circularity Profile:
- ENVEOLI2105013
- Product Certifications:
- CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
- Rohs Exemption Information:
- Yes
- Rated Breaking Capacity:
- 1610 A at 440 V
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
- [Ui] Rated Insulation Voltage:
- 1000 V
- Permissible Ambient Air Temperature Around The Device:
- -40-70°C at Uc
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Average Impedance:
- 0.00017 Ohm
- Mounting Support:
- plate
- Product Or Component Type:
- contactor
- Motor Power Kw:
- 55 kW at 230 V AC 50/60 Hz (AC-3e) || 90 kW at 400 V AC 50/60 Hz (AC-3e) || 90 kW at 415 V AC 50/60 Hz (AC-3e) || 110 kW at 440 V AC 50/60 Hz (AC-3e) || 110 kW at 500 V AC 50/60 Hz (AC-3e) || 110 kW at 690 V AC 50/60 Hz (AC-3e) || 75 kW at 1000 V AC
- Country of Origin:
- China
- Coil Technology:
- built-in bidirectional peak limiting
- Mercury Free:
- Yes
- Mechanical Durability:
- 8 Mcycles
- Inrush Power In W:
- 215 W
- Compatibility Code:
- LC1G
- Depth:
- 193 mm
- Operating Time:
- 40...70 ms closing || 15...50 ms opening
- Device Short Name:
- LC1G
- Protective Treatment:
- TH
- Eu Rohs Directive:
- Compliant with Exemptions
- Pole Contact Composition:
- 3 NO
- Overvoltage Category:
- III
- Net Weight:
- 3.6 kg
- [Ie] Rated Operational Current:
- 305 A (at <40°C) at <= 1000 V AC-1 || 185 A (at <60°C) at <= 440 V AC-3
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Uc] Control Circuit Voltage:
- 200...500 V AC 50/60 Hz || 200...500 V DC
- Poles Description:
- 3P
- China Rohs Regulation:
- X
- Ambient Air Temperature For Operation:
- -25-60°C
- Range:
- TeSys
- Range Of Product:
- TeSys Giga
- Ambient Air Temperature For Storage:
- -60-80°C
- Inrush Power In Va:
- 295-295 VA