Schneider Electric

Schneider Electric LC1G225EHEN Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 225A, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G225EHEN
MPN:
LC1G225EHEN
Condition:
New
Tightening Torque:
18 N.m
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Power Dissipation Per Pole:
20 W AC-1 - Ith 330 A || 8 W AC-3 - Ith 225 A
Compatibility Code:
LC1G
Eu Rohs Directive:
Compliant with Exemptions
Operating Time:
40...70 ms closing || 15...50 ms opening
Rated Breaking Capacity:
2050 A at 440 V
Environmental Disclosure:
ENVPEP2105013
Device Short Name:
LC1G
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Range:
TeSys
Contactor Application:
power switching || motor control
Protective Treatment:
TH
Ambient Air Temperature For Operation:
-25-60°C
Auxiliary Contact Composition:
1 NO + 1 NC
Halogen Content Performance:
Halogen free plastic parts product
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Pvc Free:
Yes
Mechanical Durability:
8 Mcycles
Weight:
3.6 kg
Color:
dark grey
Poles Description:
3P
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Rohs Exemption Information:
Yes
Mounting Support:
plate
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Ambient Air Temperature For Storage:
-60-80°C
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Width:
108 mm
Connection Pitch:
35 mm
Range Of Product:
TeSys Giga
Inrush Power In W:
445 W
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Motor Power Kw:
55 kW at 230 V AC 50/60 Hz (AC-3e) || 110 kW at 400 V AC 50/60 Hz (AC-3e) || 110 kW at 415 V AC 50/60 Hz (AC-3e) || 132 kW at 440 V AC 50/60 Hz (AC-3e) || 132 kW at 500 V AC 50/60 Hz (AC-3e) || 160 kW at 690 V AC 50/60 Hz (AC-3e) || 132 kW at 1000 V
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Hold-In Power Consumption In W:
7.8-7.8 W
Pole Contact Composition:
3 NO
Overvoltage Category:
III
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ith] Conventional Free Air Thermal Current:
330 A (at 40°C)
Maximum Horse Power Rating:
60 hp at 200/208 V 60 Hz || 75 hp at 230/240 V 60 Hz || 150 hp at 460/480 V 60 Hz || 150 hp at 575/600 V 60 Hz
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Depth:
193 mm
Hold-In Power Consumption In Va:
18.7-18.7 VA
Country of Origin:
United States
[Ie] Rated Operational Current:
330 A (at <40°C) at <= 1000 V AC-1 || 225 A (at <60°C) at <= 440 V AC-3
Irms Rated Making Capacity:
2720 A at 440 V
Sustainable Offer Status:
Green Premium product
$1,155.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 225A 132kW@440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose