Schneider Electric

Schneider Electric LC1G2654LSEA Contactor, high power, TeSys Giga, advanced version, 4 pole/NO, AC-1 <=440V 385A, 200-500VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G2654LSEA
MPN:
LC1G2654LSEA
Condition:
New
Environmental Disclosure:
ENVPEP2105013
Circularity Profile:
ENVEOLI2105013
[Ith] Conventional Free Air Thermal Current:
385 A (at 40°C)
China Rohs Regulation:
X
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Pvc Free:
Yes
Hold-In Power Consumption In Va:
16.1-16.1 VA
Contactor Application:
power switching
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Rated Breaking Capacity:
2380 A at 440 V
Rohs Exemption Information:
Yes
Range:
TeSys
Coil Technology:
built-in bidirectional peak limiting
Overvoltage Category:
III
Pole Contact Composition:
4 NO
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Weight:
8.7 kg
Poles Description:
4P
Depth:
226 mm
Mounting Support:
plate
Power Dissipation Per Pole:
20 W AC-1 - Ith 385 A || 11 W AC-3 - Ith 265 A
Tightening Torque:
35 N.m
Halogen Content Performance:
Halogen free plastic parts product
[Icw] Rated Short-Time Withstand Current:
2.2 kA - 10 s || 1.23 kA - 30 s || 0.95 kA - 1 min || 0.62 kA - 3 min || 0.48 kA - 10 min
Device Short Name:
LC1G
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Inrush Power In Va:
530-530 VA
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
Compatibility Code:
LC1G
Country of Origin:
China
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Range Of Product:
TeSys Giga
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Connection Pitch:
45 mm
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
Sustainable Offer Status:
Green Premium product
Operating Time:
40...70 ms closing || 15...50 ms opening
Auxiliary Contact Composition:
1 NO + 1 NC
Product Or Component Type:
contactor
[Ie] Rated Operational Current:
265 A (at <60°C) at <= 440 V AC-3 || 385 A (at <40°C) at <= 1000 V AC-1
Associated Fuse Rating:
315 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 400 A gG at <= 690 V
Mercury Free:
Yes
Color:
dark grey
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Hold-In Power Consumption In W:
9.0-9.0 W
$2,050.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 385A @440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose