Schneider Electric

Schneider Electric LC1G2654LSEN Contactor, high power, TeSys Giga, 4P(4NO), AC-1, <=440V 385A, standard version, 200-500V AC/DC wide band coil

(No reviews yet) Write a Review
SKU:
LC1G2654LSEN
MPN:
LC1G2654LSEN
Condition:
New
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
[Ith] Conventional Free Air Thermal Current:
385 A (at 40°C)
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Rohs Exemption Information:
Yes
Net Weight:
8.2 kg
Protective Treatment:
TH
Contactor Application:
power switching
Poles Description:
4P
Sustainable Offer Status:
Green Premium product
Power Dissipation Per Pole:
20 W AC-1 - Ith 385 A || 11 W AC-3 - Ith 265 A
Eu Rohs Directive:
Compliant with Exemptions
Inrush Power In Va:
530-530 VA
Inrush Power In W:
300 W
Mounting Support:
plate
Mechanical Durability:
8 Mcycles
Irms Rated Making Capacity:
3320 A at 440 V
Hold-In Power Consumption In W:
9-9 W
Compatibility Code:
LC1G
Country of Origin:
China
Operating Time:
40...70 ms closing || 15...50 ms opening
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Overvoltage Category:
III
Circularity Profile:
ENVEOLI2105013
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Width:
185 mm
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
China Rohs Regulation:
X
Range Of Product:
TeSys Giga
Auxiliary Contact Composition:
1 NO + 1 NC
Pole Contact Composition:
4 NO
Average Impedance:
0.000144 Ohm
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
Hold-In Power Consumption In Va:
16.1-16.1 VA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rated Breaking Capacity:
2380 A at 440 V
[Ie] Rated Operational Current:
265 A (at <60°C) at <= 440 V AC-3 || 385 A (at <40°C) at <= 1000 V AC-1
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Coil Technology:
built-in bidirectional peak limiting
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Ambient Air Temperature For Operation:
-25-60°C
Associated Fuse Rating:
315 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 400 A gG at <= 690 V
Ambient Air Temperature For Storage:
-60-80°C
Weight:
8.2 kg
Tightening Torque:
35 N.m
Environmental Disclosure:
ENVPEP2105013
Connection Pitch:
45 mm
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Depth:
226 mm
$2,050.00