Schneider Electric

Schneider Electric LC1G265EHEN Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 265A, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G265EHEN
MPN:
LC1G265EHEN
Condition:
New
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Ambient Air Temperature For Storage:
-60-80°C
Height:
225 mm
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
[Ui] Rated Insulation Voltage:
1000 V
Environmental Disclosure:
ENVPEP2105013
Circularity Profile:
ENVEOLI2105013
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Halogen Content Performance:
Halogen free plastic parts product
Device Short Name:
LC1G
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
[Icw] Rated Short-Time Withstand Current:
2.2 kA - 10 s || 1.23 kA - 30 s || 0.95 kA - 1 min || 0.62 kA - 3 min || 0.48 kA - 10 min
Pvc Free:
Yes
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Power Dissipation Per Pole:
20 W AC-1 - Ith 385 A || 11 W AC-3 - Ith 265 A
Auxiliary Contact Composition:
1 NO + 1 NC
Weight:
7.5 kg
Rated Breaking Capacity:
2380 A at 440 V
Irms Rated Making Capacity:
3320 A at 440 V
Mechanical Durability:
8 Mcycles
Hold-In Power Consumption In Va:
17.6-17.6 VA
Ambient Air Temperature For Operation:
-25-60°C
Sustainable Offer Status:
Green Premium product
Inrush Power In W:
695 W
Connection Pitch:
45 mm
Average Impedance:
0.000144 Ohm
Contactor Application:
power switching || motor control
Mounting Support:
plate
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Operating Time:
40...70 ms closing || 15...50 ms opening
Depth:
226 mm
[Ith] Conventional Free Air Thermal Current:
385 A (at 40°C)
Compatibility Code:
LC1G
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Net Weight:
7.5 kg
Rohs Exemption Information:
Yes
Coil Technology:
built-in bidirectional peak limiting
Pole Contact Composition:
3 NO
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Country of Origin:
France
China Rohs Regulation:
X
Poles Description:
3P
Mercury Free:
Yes
[Ie] Rated Operational Current:
385 A (at <40°C) at <= 1000 V AC-1 || 265 A (at <60°C) at <= 440 V AC-3
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
$1,370.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 265A 160kW@440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose