Schneider Electric LC1G3304EHEN Contactor, high power, TeSys Giga, standard version, 4 pole/NO, AC-1 <=440V 440A, 48-130VAC/DC coil
Schneider Electric
$1,950.00
TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 440A @440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
- [Ith] Conventional Free Air Thermal Current:
- 440 A (at 40°C)
- Depth:
- 226 mm
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Mounting Support:
- plate
- Net Weight:
- 8.2 kg
- Range Of Product:
- TeSys Giga
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
- Mechanical Robustness:
- vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
- Safety Reliability Level:
- B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
- Hold-In Power Consumption In W:
- 7.8-7.8 W
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Eu Rohs Directive:
- Compliant with Exemptions
- Maximum Operating Rate:
- 600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
- [Icw] Rated Short-Time Withstand Current:
- 2.65 kA - 10 s || 1.8 kA - 30 s || 1.3 kA - 1 min || 0.9 kA - 3 min || 0.75 kA - 10 min
- China Rohs Regulation:
- X
- Color:
- dark grey
- Coil Technology:
- built-in bidirectional peak limiting
- Operating Time:
- 40...70 ms closing || 15...50 ms opening
- Utilisation Category:
- AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
- Control Circuit Voltage Limits:
- operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
- Associated Fuse Rating:
- 400 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 500 A gG at <= 690 V
- Connection Pitch:
- 45 mm
- Halogen Content Performance:
- Halogen free plastic parts product
- Rohs Exemption Information:
- Yes
- Range:
- TeSys
- [Ui] Rated Insulation Voltage:
- 1000 V
- Ambient Air Temperature For Storage:
- -60-80°C
- Average Impedance:
- 0.000144 Ohm
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Weight:
- 8.2 kg
- Pole Contact Composition:
- 4 NO
- Poles Description:
- 4P
- Hold-In Power Consumption In Va:
- 17.6-17.6 VA
- Mechanical Durability:
- 8 Mcycles
- Device Short Name:
- LC1G
- Contactor Application:
- power switching
- Permissible Ambient Air Temperature Around The Device:
- -40-70°C at Uc
- [Ue] Rated Operational Voltage:
- <= 1000 V AC 50/60 Hz || <= 460 V DC
- Product Or Component Type:
- contactor
- Country of Origin:
- China
- Ip Degree Of Protection:
- IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
- Overvoltage Category:
- III
- Tightening Torque:
- 35 N.m
- [Uc] Control Circuit Voltage:
- 48...130 V AC 50/60 Hz || 48...130 V DC
- Inrush Power In W:
- 695 W