Schneider Electric

Schneider Electric LC1G3304LSEN Contactor, high power, TeSys Giga, 4P(4NO), AC-1, <=440V 440A, standard version, 200-500V AC/DC wide band coil

(No reviews yet) Write a Review
SKU:
LC1G3304LSEN
MPN:
LC1G3304LSEN
Condition:
New
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
China Rohs Regulation:
X
Hold-In Power Consumption In W:
9-9 W
Compatibility Code:
LC1G
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
Irms Rated Making Capacity:
3830 A at 440 V
Mounting Support:
plate
Country of Origin:
China
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Mercury Free:
Yes
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Net Weight:
8.2 kg
Tightening Torque:
35 N.m
Range:
TeSys
Auxiliary Contact Composition:
1 NO + 1 NC
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
Mechanical Durability:
8 Mcycles
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
Pole Contact Composition:
4 NO
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Ambient Air Temperature For Storage:
-60-80°C
Device Short Name:
LC1G
[Ith] Conventional Free Air Thermal Current:
440 A (at 40°C)
Coil Technology:
built-in bidirectional peak limiting
Depth:
226 mm
Ambient Air Temperature For Operation:
-25-60°C
Operating Time:
40...70 ms closing || 15...50 ms opening
Overvoltage Category:
III
[Uimp] Rated Impulse Withstand Voltage:
8 kV
[Ui] Rated Insulation Voltage:
1000 V
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² -
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
Environmental Disclosure:
ENVPEP2105013
Inrush Power In W:
300 W
Associated Fuse Rating:
400 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 500 A gG at <= 690 V
Hold-In Power Consumption In Va:
16.1-16.1 VA
Product Or Component Type:
contactor
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Inrush Power In Va:
530-530 VA
Eu Rohs Directive:
Compliant with Exemptions
[Ie] Rated Operational Current:
330 A (at <60°C) at <= 440 V AC-3 || 440 A (at <40°C) at <= 1000 V AC-1
Contactor Application:
power switching
$2,240.00