Schneider Electric LC1G330BEEA Contactor, high power, TeSys Giga, advanced version, AC-3, <= 440V, 330A, 3 pole/NO, 24-48VAC/DC coil
Schneider Electric
$1,720.00
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 330A 200kW@440V. It provides a 24-48V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Pvc Free:
- Yes
- Rated Breaking Capacity:
- 2940 A at 440 V
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Depth:
- 226 mm
- [Ue] Rated Operational Voltage:
- <= 1000 V AC 50/60 Hz || <= 460 V DC
- Connection Pitch:
- 45 mm
- Associated Fuse Rating:
- 400 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 500 A gG at <= 690 V
- Average Impedance:
- 0.000144 Ohm
- Hold-In Power Consumption In Va:
- 17.9-17.9 VA
- Motor Power Kw:
- 90 kW at 230 V AC 50/60 Hz (AC-3e) || 160 kW at 400 V AC 50/60 Hz (AC-3e) || 160 kW at 415 V AC 50/60 Hz (AC-3e) || 185 kW at 440 V AC 50/60 Hz (AC-3e) || 200 kW at 500 V AC 50/60 Hz (AC-3e) || 220 kW at 690 V AC 50/60 Hz (AC-3e) || 185 kW at 1000 V
- Eu Rohs Directive:
- Compliant with Exemptions
- Pole Contact Composition:
- 3 NO
- Maximum Horse Power Rating:
- 100 hp at 200/208 V 60 Hz || 125 hp at 230/240 V 60 Hz || 250 hp at 460/480 V 60 Hz || 300 hp at 575/600 V 60 Hz
- Rohs Exemption Information:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Maximum Operating Rate:
- 600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
- Ip Degree Of Protection:
- IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
- Inrush Power In Va:
- 540-540 VA
- Range Of Product:
- TeSys Giga
- Color:
- dark grey
- Safety Reliability Level:
- B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
- Net Weight:
- 8.2 kg
- Inrush Power In W:
- 380 W
- Compatibility Code:
- LC1G
- Product Or Component Type:
- contactor
- Weight:
- 8.2 kg
- Connections - Terminals:
- power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
- Height:
- 290 mm
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
- Tightening Torque:
- 35 N.m
- [Ui] Rated Insulation Voltage:
- 1000 V
- Coil Technology:
- built-in bidirectional peak limiting
- [Uc] Control Circuit Voltage:
- 24...48 V AC 50/60 Hz || 24...48 V DC
- [Ith] Conventional Free Air Thermal Current:
- 440 A (at 40°C)
- Circularity Profile:
- ENVEOLI2105013
- China Rohs Regulation:
- X
- Product Certifications:
- CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
- Protective Treatment:
- TH
- Control Circuit Voltage Limits:
- operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Mercury Free:
- Yes
- [Icw] Rated Short-Time Withstand Current:
- 2.65 kA - 10 s || 1.8 kA - 30 s || 1.3 kA - 1 min || 0.9 kA - 3 min || 0.75 kA - 10 min
- Poles Description:
- 3P
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
- Ambient Air Temperature For Operation:
- -25-60°C
- Mechanical Durability:
- 8 Mcycles
- Operating Time:
- 40...70 ms closing || 15...50 ms opening