Schneider Electric

Schneider Electric LC1G330LSEA Contactor, high power, TeSys Giga, advanced version, 3 pole/NO, AC-3 <=440V 330A, 200-500VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G330LSEA
MPN:
LC1G330LSEA
Condition:
New
[Icw] Rated Short-Time Withstand Current:
2.65 kA - 10 s || 1.8 kA - 30 s || 1.3 kA - 1 min || 0.9 kA - 3 min || 0.75 kA - 10 min
Inrush Power In W:
300 W
Motor Power Kw:
90 kW at 230 V AC 50/60 Hz (AC-3e) || 160 kW at 400 V AC 50/60 Hz (AC-3e) || 160 kW at 415 V AC 50/60 Hz (AC-3e) || 185 kW at 440 V AC 50/60 Hz (AC-3e) || 200 kW at 500 V AC 50/60 Hz (AC-3e) || 220 kW at 690 V AC 50/60 Hz (AC-3e) || 185 kW at 1000 V
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Contactor Application:
power switching || motor control
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Ambient Air Temperature For Operation:
-25-60°C
Sustainable Offer Status:
Green Premium product
Range:
TeSys
Auxiliary Contact Composition:
1 NO + 1 NC
Compatibility Code:
LC1G
Eu Rohs Directive:
Compliant with Exemptions
Overvoltage Category:
III
Protective Treatment:
TH
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
35 N.m
Associated Fuse Rating:
400 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 500 A gG at <= 690 V
Average Impedance:
0.000144 Ohm
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Rohs Exemption Information:
Yes
Weight:
8.2 kg
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
Device Short Name:
LC1G
Mechanical Durability:
8 Mcycles
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
China Rohs Regulation:
X
[Ie] Rated Operational Current:
440 A (at <40°C) at <= 1000 V AC-1 || 330 A (at <60°C) at <= 440 V AC-3
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Depth:
226 mm
Halogen Content Performance:
Halogen free plastic parts product
Ambient Air Temperature For Storage:
-60-80°C
Pole Contact Composition:
3 NO
Environmental Disclosure:
ENVPEP2105013
Inrush Power In Va:
530-530 VA
Operating Time:
40...70 ms closing || 15...50 ms opening
Range Of Product:
TeSys Giga
Color:
dark grey
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Rated Breaking Capacity:
2940 A at 440 V
Hold-In Power Consumption In Va:
16.1-16.1 VA
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Connection Pitch:
45 mm
Mounting Support:
plate
$1,720.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 330A 200kW@440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.