Schneider Electric LC1G330LSEN Contactor, high power, TeSys Giga, 3P(3NO), AC-3, <=440V 330A, standard version, 200-500V AC/DC wide band coil
Schneider Electric
$1,720.00
Contactor, high power, TeSys Giga, 3P(3NO), AC-3, <=440V 330A, standard version, 200-500V AC/DC wide band coil
- Operating Time:
- 40...70 ms closing || 15...50 ms opening
- Inrush Power In W:
- 300 W
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Coil Technology:
- built-in bidirectional peak limiting
- [Icw] Rated Short-Time Withstand Current:
- 2.65 kA - 10 s || 1.8 kA - 30 s || 1.3 kA - 1 min || 0.9 kA - 3 min || 0.75 kA - 10 min
- Safety Reliability Level:
- B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
- Weight:
- 7.5 kg
- Product Certifications:
- CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
- Irms Rated Making Capacity:
- 3830 A at 440 V
- Connection Pitch:
- 45 mm
- Pole Contact Composition:
- 3 NO
- Rohs Exemption Information:
- Yes
- Permissible Ambient Air Temperature Around The Device:
- -40-70°C at Uc
- Country of Origin:
- China
- Sustainable Offer Status:
- Green Premium product
- Maximum Operating Rate:
- 600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
- Ambient Air Temperature For Operation:
- -25-60°C
- Ambient Air Temperature For Storage:
- -60-80°C
- [Ie] Rated Operational Current:
- 440 A (at <40°C) at <= 1000 V AC-1 || 330 A (at <60°C) at <= 440 V AC-3
- [Ui] Rated Insulation Voltage:
- 1000 V
- [Uc] Control Circuit Voltage:
- 200...500 V AC 50/60 Hz || 200...500 V DC
- Depth:
- 226 mm
- Compatibility Code:
- LC1G
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
- Contactor Application:
- power switching || motor control
- Mercury Free:
- Yes
- China Rohs Regulation:
- X
- Circularity Profile:
- ENVEOLI2105013
- Environmental Disclosure:
- ENVPEP2105013
- Hold-In Power Consumption In W:
- 9-9 W
- Control Circuit Voltage Limits:
- operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
- Range Of Product:
- TeSys Giga
- Maximum Horse Power Rating:
- 100 hp at 200/208 V 60 Hz || 125 hp at 230/240 V 60 Hz || 250 hp at 460/480 V 60 Hz || 300 hp at 575/600 V 60 Hz
- Device Short Name:
- LC1G
- Product Or Component Type:
- contactor
- Connections - Terminals:
- power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
- Color:
- dark grey
- Overvoltage Category:
- III
- Protective Treatment:
- TH
- Mounting Support:
- plate
- Poles Description:
- 3P
- Rated Breaking Capacity:
- 2940 A at 440 V
- Range:
- TeSys
- Hold-In Power Consumption In Va:
- 16.1-16.1 VA
- Auxiliary Contact Composition:
- 1 NO + 1 NC