Schneider Electric

Schneider Electric LC1G4004EHEN Contactor, high power, TeSys Giga, standard version, 4 pole/NO, AC-1 <=440V 550A, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G4004EHEN
MPN:
LC1G4004EHEN
Condition:
New
Weight:
8.2 kg
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Associated Fuse Rating:
500 A aM at <= 440 V for motor || 315 A aM at <= 690 V for motor || 630 A gG at <= 690 V
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Product Or Component Type:
contactor
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
Color:
dark grey
Country of Origin:
China
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
Overvoltage Category:
III
China Rohs Regulation:
X
Coil Technology:
built-in bidirectional peak limiting
Halogen Content Performance:
Halogen free plastic parts product
Poles Description:
4P
Ambient Air Temperature For Storage:
-60-80°C
Hold-In Power Consumption In W:
7.8-7.8 W
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Tightening Torque:
35 N.m
Hold-In Power Consumption In Va:
17.6-17.6 VA
Operating Time:
40...70 ms closing || 15...50 ms opening
Range:
TeSys
Environmental Disclosure:
ENVPEP2105013
[Ui] Rated Insulation Voltage:
1000 V
Depth:
226 mm
[Ith] Conventional Free Air Thermal Current:
550 A (at 40°C)
Protective Treatment:
TH
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Contactor Application:
power switching
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Auxiliary Contact Composition:
1 NO + 1 NC
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Mounting Support:
plate
Inrush Power In Va:
965-965 VA
Net Weight:
8.2 kg
Pole Contact Composition:
4 NO
Irms Rated Making Capacity:
5090 A at 440 V
Range Of Product:
TeSys Giga
Compatibility Code:
LC1G
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-25-60°C
Circularity Profile:
ENVEOLI2105013
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
$2,225.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 550A @440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose