Schneider Electric

Schneider Electric LC1G5004EHEA Contactor, high power, TeSys Giga, advanced version, AC-1, <= 440V, 700A, 4 pole/NO, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G5004EHEA
MPN:
LC1G5004EHEA
Condition:
New
[Ui] Rated Insulation Voltage:
1000 V
Inrush Power In W:
360 W
Hold-In Power Consumption In Va:
11.7-11.7 VA
Hold-In Power Consumption In W:
8.3-8.3 W
Operating Time:
40...70 ms closing || 15...50 ms opening
Coil Technology:
built-in bidirectional peak limiting
Compatibility Code:
LC1G
Protective Treatment:
TH
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Ambient Air Temperature For Operation:
-25-60°C
Height:
290 mm
Color:
dark grey
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
Weight:
8.7 kg
Mechanical Durability:
8 Mcycles
Mercury Free:
Yes
Circularity Profile:
ENVEOLI2105013
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Average Impedance:
0.00008 Ohm
Power Dissipation Per Pole:
40 W AC-1 - Ith 700 A || 20 W AC-3 - Ith 500 A
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Connection Pitch:
45 mm
Maximum Horse Power Rating:
150 hp at 200/208 V 60 Hz || 200 hp at 230/240 V 60 Hz || 400 hp at 460/480 V 60 Hz || 450 hp at 575/600 V 60 Hz
Rohs Exemption Information:
Yes
Irms Rated Making Capacity:
5090 A at 440 V
[Ith] Conventional Free Air Thermal Current:
700 A (at 40°C)
China Rohs Regulation:
X
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
[Icw] Rated Short-Time Withstand Current:
4.0 kA - 10 s || 2.8 kA - 30 s || 2.2 kA - 1 min || 1.5 kA - 3 min || 1.2 kA - 10 min
[Ie] Rated Operational Current:
500 A (at <60°C) at <= 440 V AC-3 || 700 A (at <40°C) at <= 1000 V AC-1
Depth:
226 mm
Poles Description:
4P
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Mounting Support:
plate
Ambient Air Temperature For Storage:
-60-80°C
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Device Short Name:
LC1G
Net Weight:
8.7 kg
Range Of Product:
TeSys Giga
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Environmental Disclosure:
ENVPEP2105013
Inrush Power In Va:
450-450 VA
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Overvoltage Category:
III
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Contactor Application:
power switching
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
$3,840.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 700A @440V. It provides a 48-130V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose