New
Overvoltage Category:
III
Ambient Air Temperature For Operation:
-25-60°C
Eu Rohs Directive:
Compliant with Exemptions
Hold-In Power Consumption In W:
7.8-7.8 W
Width:
185 mm
Depth:
226 mm
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Rohs Exemption Information:
Yes
Coil Technology:
built-in bidirectional peak limiting
Poles Description:
4P
Product Or Component Type:
contactor
Country of Origin:
China
Environmental Disclosure:
ENVPEP2105013
Ambient Air Temperature For Storage:
-60-80°C
[Ie] Rated Operational Current:
500 A (at <60°C) at <= 440 V AC-3 || 700 A (at <40°C) at <= 1000 V AC-1
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
Mercury Free:
Yes
Irms Rated Making Capacity:
5090 A at 440 V
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Circularity Profile:
ENVEOLI2105013
Operating Time:
40...70 ms closing || 15...50 ms opening
Power Dissipation Per Pole:
40 W AC-1 - Ith 700 A || 20 W AC-3 - Ith 500 A
Protective Treatment:
TH
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Mechanical Durability:
8 Mcycles
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Color:
dark grey
Compatibility Code:
LC1G
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² -
Connection Pitch:
45 mm
Pole Contact Composition:
4 NO
Associated Fuse Rating:
500 A aM at <= 440 V for motor || 400 A aM at <= 690 V for motor || 800 A gG at <= 690 V
Sustainable Offer Status:
Green Premium product
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Inrush Power In Va:
965-965 VA
Range:
TeSys
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
TeSys Giga
Auxiliary Contact Composition:
1 NO + 1 NC
Inrush Power In W:
760 W
China Rohs Regulation:
X
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Mounting Support:
plate
Hold-In Power Consumption In Va:
17.6-17.6 VA
Contactor Application:
power switching
Device Short Name:
LC1G
$3,340.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 700A @440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.