Schneider Electric

Schneider Electric LC1G5004KUEN Contactor, high power, TeSys Giga, standard version, 4 pole/NO, AC-1 <=440V 700A, 100-250VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G5004KUEN
MPN:
LC1G5004KUEN
Condition:
New
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Width:
185 mm
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Circularity Profile:
ENVEOLI2105013
Range Of Product:
TeSys Giga
[Ie] Rated Operational Current:
500 A (at <60°C) at <= 440 V AC-3 || 700 A (at <40°C) at <= 1000 V AC-1
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² -
Protective Treatment:
TH
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Inrush Power In Va:
750-750 VA
Range:
TeSys
Eu Rohs Directive:
Compliant with Exemptions
[Ith] Conventional Free Air Thermal Current:
700 A (at 40°C)
Pole Contact Composition:
4 NO
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Mercury Free:
Yes
Country of Origin:
China
Device Short Name:
LC1G
Pvc Free:
Yes
Mechanical Durability:
8 Mcycles
Weight:
8.2 kg
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Average Impedance:
0.00008 Ohm
Hold-In Power Consumption In Va:
15.5-15.5 VA
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Connection Pitch:
45 mm
China Rohs Regulation:
X
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Rated Breaking Capacity:
4600 A at 440 V
Tightening Torque:
35 N.m
Color:
dark grey
Ambient Air Temperature For Operation:
-25-60°C
Contactor Application:
power switching
Hold-In Power Consumption In W:
9.3-9.3 W
Ambient Air Temperature For Storage:
-60-80°C
Rohs Exemption Information:
Yes
Overvoltage Category:
III
Halogen Content Performance:
Halogen free plastic parts product
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Compatibility Code:
LC1G
Coil Technology:
built-in bidirectional peak limiting
Product Or Component Type:
contactor
Inrush Power In W:
660 W
Environmental Disclosure:
ENVPEP2105013
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
$3,340.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 700A @440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose