Schneider Electric

Schneider Electric LC1G500EHEA Contactor, high power, TeSys Giga, advanced version, AC-3, <= 440V, 500A, 3 pole/NO, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G500EHEA
MPN:
LC1G500EHEA
Condition:
New
Tightening Torque:
35 N.m
Pole Contact Composition:
3 NO
Inrush Power In W:
360 W
Inrush Power In Va:
450-450 VA
Overvoltage Category:
III
Eu Rohs Directive:
Compliant with Exemptions
Device Short Name:
LC1G
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Average Impedance:
0.00008 Ohm
Operating Time:
40...70 ms closing || 15...50 ms opening
Poles Description:
3P
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Ambient Air Temperature For Operation:
-25-60°C
Hold-In Power Consumption In Va:
11.7-11.7 VA
Sustainable Offer Status:
Green Premium product
Product Or Component Type:
contactor
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Rohs Exemption Information:
Yes
Color:
dark grey
Auxiliary Contact Composition:
1 NO + 1 NC
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP2105013
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Pvc Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
[Ie] Rated Operational Current:
700 A (at <40°C) at <= 1000 V AC-1 || 500 A (at <60°C) at <= 440 V AC-3
Associated Fuse Rating:
500 A aM at <= 440 V for motor || 400 A aM at <= 690 V for motor || 800 A gG at <= 690 V
Range Of Product:
TeSys Giga
Hold-In Power Consumption In W:
8.3-8.3 W
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Motor Power Kw:
147 kW at 230 V AC 50/60 Hz (AC-3e) || 250 kW at 400 V AC 50/60 Hz (AC-3e) || 250 kW at 415 V AC 50/60 Hz (AC-3e) || 280 kW at 440 V AC 50/60 Hz (AC-3e) || 315 kW at 500 V AC 50/60 Hz (AC-3e) || 355 kW at 690 V AC 50/60 Hz (AC-3e) || 335 kW at 1000 V
[Icw] Rated Short-Time Withstand Current:
4.0 kA - 10 s || 2.8 kA - 30 s || 2.2 kA - 1 min || 1.5 kA - 3 min || 1.2 kA - 10 min
Power Dissipation Per Pole:
40 W AC-1 - Ith 700 A || 20 W AC-3 - Ith 500 A
Connection Pitch:
45 mm
China Rohs Regulation:
X
Protective Treatment:
TH
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Country of Origin:
China
Rated Breaking Capacity:
4600 A at 440 V
Depth:
226 mm
[Ith] Conventional Free Air Thermal Current:
700 A (at 40°C)
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Compatibility Code:
LC1G
$2,950.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 500A 315kW@440V. It provides a 48-130V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose