TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 500A 315kW@440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
- Coil Technology:
- built-in bidirectional peak limiting
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
- Hold-In Power Consumption In W:
- 7.8-7.8 W
- Rated Breaking Capacity:
- 4600 A at 440 V
- Range:
- TeSys
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Inrush Power In Va:
- 965-965 VA
- Range Of Product:
- TeSys Giga
- [Ie] Rated Operational Current:
- 700 A (at <40°C) at <= 1000 V AC-1 || 500 A (at <60°C) at <= 440 V AC-3
- Tightening Torque:
- 35 N.m
- Overvoltage Category:
- III
- Maximum Horse Power Rating:
- 150 hp at 200/208 V 60 Hz || 200 hp at 230/240 V 60 Hz || 400 hp at 460/480 V 60 Hz || 450 hp at 575/600 V 60 Hz
- Height:
- 225 mm
- Rohs Exemption Information:
- Yes
- Device Short Name:
- LC1G
- Associated Fuse Rating:
- 500 A aM at <= 440 V for motor || 400 A aM at <= 690 V for motor || 800 A gG at <= 690 V
- Control Circuit Voltage Limits:
- operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
- Sustainable Offer Status:
- Green Premium product
- Connections - Terminals:
- power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
- Connection Pitch:
- 45 mm
- [Ue] Rated Operational Voltage:
- <= 1000 V AC 50/60 Hz || <= 460 V DC
- Pole Contact Composition:
- 3 NO
- Pvc Free:
- Yes
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Poles Description:
- 3P
- [Uc] Control Circuit Voltage:
- 48...130 V AC 50/60 Hz || 48...130 V DC
- Ambient Air Temperature For Storage:
- -60-80°C
- Product Certifications:
- CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
- Color:
- dark grey
- Contactor Application:
- power switching || motor control
- Depth:
- 226 mm
- Mercury Free:
- Yes
- [Icw] Rated Short-Time Withstand Current:
- 4.0 kA - 10 s || 2.8 kA - 30 s || 2.2 kA - 1 min || 1.5 kA - 3 min || 1.2 kA - 10 min
- Mechanical Robustness:
- vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
- Circularity Profile:
- ENVEOLI2105013
- Hold-In Power Consumption In Va:
- 17.6-17.6 VA
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Ambient Air Temperature For Operation:
- -25-60°C
- Power Dissipation Per Pole:
- 40 W AC-1 - Ith 700 A || 20 W AC-3 - Ith 500 A
- Mounting Support:
- plate
- Protective Treatment:
- TH
- Product Or Component Type:
- contactor
- Average Impedance:
- 0.00008 Ohm
- Mechanical Durability:
- 8 Mcycles
- Inrush Power In W:
- 760 W
- Ip Degree Of Protection:
- IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
- Weight:
- 7.5 kg