Schneider Electric

Schneider Electric LC1G500KUEN Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 500A, 100-250VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G500KUEN
MPN:
LC1G500KUEN
Condition:
New
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Contactor Application:
power switching || motor control
Auxiliary Contact Composition:
1 NO + 1 NC
Overvoltage Category:
III
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Country of Origin:
France
Compatibility Code:
LC1G
Operating Time:
40...70 ms closing || 15...50 ms opening
Coil Technology:
built-in bidirectional peak limiting
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Inrush Power In W:
660 W
Protective Treatment:
TH
Motor Power Kw:
147 kW at 230 V AC 50/60 Hz (AC-3e) || 250 kW at 400 V AC 50/60 Hz (AC-3e) || 250 kW at 415 V AC 50/60 Hz (AC-3e) || 280 kW at 440 V AC 50/60 Hz (AC-3e) || 315 kW at 500 V AC 50/60 Hz (AC-3e) || 355 kW at 690 V AC 50/60 Hz (AC-3e) || 335 kW at 1000 V
Weight:
7.5 kg
Mechanical Durability:
8 Mcycles
Rated Breaking Capacity:
4600 A at 440 V
Hold-In Power Consumption In W:
9.3-9.3 W
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Associated Fuse Rating:
500 A aM at <= 440 V for motor || 400 A aM at <= 690 V for motor || 800 A gG at <= 690 V
Pole Contact Composition:
3 NO
Average Impedance:
0.00008 Ohm
Halogen Content Performance:
Halogen free plastic parts product
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
Range:
TeSys
Device Short Name:
LC1G
Hold-In Power Consumption In Va:
15.5-15.5 VA
China Rohs Regulation:
X
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Power Dissipation Per Pole:
40 W AC-1 - Ith 700 A || 20 W AC-3 - Ith 500 A
Pvc Free:
Yes
Poles Description:
3P
[Ith] Conventional Free Air Thermal Current:
700 A (at 40°C)
Maximum Horse Power Rating:
150 hp at 200/208 V 60 Hz || 200 hp at 230/240 V 60 Hz || 400 hp at 460/480 V 60 Hz || 450 hp at 575/600 V 60 Hz
Ambient Air Temperature For Storage:
-60-80°C
Connection Pitch:
45 mm
Tightening Torque:
35 N.m
Circularity Profile:
ENVEOLI2105013
Inrush Power In Va:
750-750 VA
Range Of Product:
TeSys Giga
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP2105013
Product Or Component Type:
contactor
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Eu Rohs Directive:
Compliant with Exemptions
$2,570.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 500A 315kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.