Schneider Electric

Schneider Electric LC1G500LSEA Contactor, high power, TeSys Giga, advanced version, 3 pole/NO, AC-3 <=440V 500A, 200-500VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G500LSEA
MPN:
LC1G500LSEA
Condition:
New
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
Protective Treatment:
TH
Hold-In Power Consumption In Va:
15.4-15.4 VA
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Connection Pitch:
45 mm
[Icw] Rated Short-Time Withstand Current:
4.0 kA - 10 s || 2.8 kA - 30 s || 2.2 kA - 1 min || 1.5 kA - 3 min || 1.2 kA - 10 min
Contactor Application:
power switching || motor control
[Ui] Rated Insulation Voltage:
1000 V
Tightening Torque:
35 N.m
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Range Of Product:
TeSys Giga
Pvc Free:
Yes
Ambient Air Temperature For Storage:
-60-80°C
Mechanical Durability:
8 Mcycles
Halogen Content Performance:
Halogen free plastic parts product
Color:
dark grey
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
China Rohs Regulation:
X
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Mounting Support:
plate
Country of Origin:
China
Mercury Free:
Yes
Range:
TeSys
Operating Time:
40...70 ms closing || 15...50 ms opening
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Ambient Air Temperature For Operation:
-25-60°C
Compatibility Code:
LC1G
Product Or Component Type:
contactor
Eu Rohs Directive:
Compliant with Exemptions
Inrush Power In W:
300 W
Motor Power Kw:
147 kW at 230 V AC 50/60 Hz (AC-3e) || 250 kW at 400 V AC 50/60 Hz (AC-3e) || 250 kW at 415 V AC 50/60 Hz (AC-3e) || 280 kW at 440 V AC 50/60 Hz (AC-3e) || 315 kW at 500 V AC 50/60 Hz (AC-3e) || 355 kW at 690 V AC 50/60 Hz (AC-3e) || 335 kW at 1000 V
Overvoltage Category:
III
Net Weight:
8.2 kg
Circularity Profile:
ENVEOLI2105013
Sustainable Offer Status:
Green Premium product
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Coil Technology:
built-in bidirectional peak limiting
Poles Description:
3P
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Inrush Power In Va:
535-535 VA
Maximum Horse Power Rating:
150 hp at 200/208 V 60 Hz || 200 hp at 230/240 V 60 Hz || 400 hp at 460/480 V 60 Hz || 450 hp at 575/600 V 60 Hz
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
$2,950.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 500A 315kW@440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.