Schneider Electric LC1G630EHEA Contactor, high power, TeSys Giga, advanced version, AC-3, <= 440V, 630A, 3 pole/NO, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G630EHEA
MPN:
LC1G630EHEA
Condition:
New
Contactor Application:
power switching || motor control
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connection Pitch:
70 mm
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Range Of Product:
TeSys Giga
Pvc Free:
Yes
Coil Technology:
built-in bidirectional peak limiting
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Associated Fuse Rating:
630 A aM at <= 440 V for motor || 500 A aM at <= 690 V for motor || 1250 A gG at <= 690 V
Protective Treatment:
TH
[Ie] Rated Operational Current:
1050 A (at <40°C) at <= 1000 V AC-1 || 630 A (at <60°C) at <= 440 V AC-3
Rohs Exemption Information:
Yes
Irms Rated Making Capacity:
7220 A at 440 V
Overvoltage Category:
III
Inrush Power In W:
440 W
Maximum Horse Power Rating:
250 hp at 200/208 V 60 Hz || 300 hp at 230/240 V 60 Hz || 600 hp at 460/480 V 60 Hz || 700 hp at 575/600 V 60 Hz
Range:
TeSys
Mechanical Durability:
5 Mcycles
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Compatibility Code:
LC1G
Device Short Name:
LC1G
Circularity Profile:
ENVEOLI2105013
Product Or Component Type:
contactor
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Poles Description:
3P
Tightening Torque:
58 N.m
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Net Weight:
17.3 kg
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Ambient Air Temperature For Operation:
-25-60°C
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
X
Eu Rohs Directive:
Compliant with Exemptions
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 52 x 20 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Inrush Power In Va:
560-560 VA
Rated Breaking Capacity:
5550 A at 440 V
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Operating Time:
40...70 ms closing || 15...50 ms opening
Weight:
17.3 kg
Safety Reliability Level:
B10d = 100000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 1800000 cycles contactor with mechanical load EN/ISO 13849-1
Pole Contact Composition:
3 NO
[Ith] Conventional Free Air Thermal Current:
1050 A (at 40°C)
$3,950.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 630A 400kW@440V. It provides a 48-130V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 324mm x 210mm x 248mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.