Schneider Electric LC1G8004EHEN Contactor, high power, TeSys Giga 800, 4 pole/NO, AC-1 <=440V 1050A, 48-130VAC/DC coil
Schneider Electric
$5,320.00
TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 1050A @440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 324mm x 280mm x 248mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
- Halogen Content Performance:
- Halogen free plastic parts product
- Associated Fuse Rating:
- 800 A aM at <= 440 V for motor || 630 A aM at <= 690 V for motor || 1250 A gG at <= 690 V
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
- Overvoltage Category:
- III
- Connection Pitch:
- 70 mm
- [Icw] Rated Short-Time Withstand Current:
- 5.5 kA - 10 s || 4.6 kA - 30 s || 3.6 kA - 1 min || 2.6 kA - 3 min || 1.7 kA - 10 min
- Range:
- TeSys
- China Rohs Regulation:
- X
- Compatibility Code:
- LC1G
- Weight:
- 18 kg
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ui] Rated Insulation Voltage:
- 1000 V
- Ambient Air Temperature For Storage:
- -60-80°C
- Net Weight:
- 18 kg
- Device Short Name:
- LC1G
- Circularity Profile:
- ENVEOLI2105013
- Power Dissipation Per Pole:
- 70 W AC-1 - Ith 1050 A || 42 W AC-3 - Ith 800 A
- [Ie] Rated Operational Current:
- 800 A (at <60°C) at <= 440 V AC-3 || 1050 A (at <40°C) at <= 1000 V AC-1
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Operating Time:
- 40...70 ms closing || 15...50 ms opening
- Hold-In Power Consumption In Va:
- 18.7-18.7 VA
- Country of Origin:
- Singapore
- Product Certifications:
- CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
- Depth:
- 266 mm
- [Uc] Control Circuit Voltage:
- 48...130 V AC 50/60 Hz || 48...130 V DC
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Contactor Application:
- power switching
- Color:
- dark grey
- Ambient Air Temperature For Operation:
- -25-60°C
- Inrush Power In W:
- 790 W
- Ip Degree Of Protection:
- IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
- Mechanical Robustness:
- vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
- Pvc Free:
- Yes
- Tightening Torque:
- 58 N.m
- Average Impedance:
- 0.000065 Ohm
- Environmental Disclosure:
- ENVPEP2105013
- Product Or Component Type:
- contactor
- Mercury Free:
- Yes
- Range Of Product:
- TeSys Giga
- Connections - Terminals:
- power circuit: bar 2 - busbar cross section: 52 x 20 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
- Rohs Exemption Information:
- Yes
- Coil Technology:
- built-in bidirectional peak limiting
- Permissible Ambient Air Temperature Around The Device:
- -40-70°C at Uc
- Irms Rated Making Capacity:
- 7640 A at 440 V
- Eu Rohs Directive:
- Compliant with Exemptions
- [Ith] Conventional Free Air Thermal Current:
- 1050 A (at 40°C)