Irms Rated Making Capacity:
7640 A at 440 V
Halogen Content Performance:
Halogen free plastic parts product
Inrush Power In Va:
990-990 VA
Range Of Product:
TeSys Giga
Compatibility Code:
LC1G
Depth:
266 mm
Protective Treatment:
TH
Power Dissipation Per Pole:
70 W AC-1 - Ith 1050 A || 42 W AC-3 - Ith 800 A
Ambient Air Temperature For Storage:
-60-80°C
Motor Power Kw:
200 kW at 230 V AC 50/60 Hz (AC-3e) || 335 kW at 400 V AC 50/60 Hz (AC-3e) || 355 kW at 415 V AC 50/60 Hz (AC-3e) || 375 kW at 440 V AC 50/60 Hz (AC-3e) || 425 kW at 500 V AC 50/60 Hz (AC-3e) || 560 kW at 690 V AC 50/60 Hz (AC-3e) || 450 kW at 1000 V
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Tightening Torque:
58 N.m
Color:
dark grey
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Net Weight:
14.2 kg
Hold-In Power Consumption In W:
9.5-9.5 W
Mercury Free:
Yes
Average Impedance:
0.000065 Ohm
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Weight:
14.2 kg
Poles Description:
3P
Sustainable Offer Status:
Green Premium product
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Connection Pitch:
70 mm
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Operating Time:
40...70 ms closing || 15...50 ms opening
Contactor Application:
power switching || motor control
Product Or Component Type:
contactor
Pole Contact Composition:
3 NO
Hold-In Power Consumption In Va:
18.7-18.7 VA
Country of Origin:
France
[Icw] Rated Short-Time Withstand Current:
5.5 kA - 10 s || 4.6 kA - 30 s || 3.6 kA - 1 min || 2.6 kA - 3 min || 1.7 kA - 10 min
Mounting Support:
plate
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Rohs Exemption Information:
Yes
Range:
TeSys
Eu Rohs Directive:
Compliant with Exemptions
Inrush Power In W:
790 W
Ambient Air Temperature For Operation:
-25-60°C
Environmental Disclosure:
ENVPEP2105013
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Overvoltage Category:
III
Pvc Free:
Yes
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
$4,090.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 800A 450kW@440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 324mm x 210mm x 248mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.