Schneider Electric

Schneider Electric LC1G800LSEA Contactor, high power, TeSys Giga, advanced version, AC-3, <= 440V, 800A, 3 pole/NO, 200-500VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G800LSEA
MPN:
LC1G800LSEA
Condition:
New
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 52 x 20 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Connection Pitch:
70 mm
Depth:
266 mm
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Ambient Air Temperature For Storage:
-60-80°C
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Motor Power Kw:
200 kW at 230 V AC 50/60 Hz (AC-3e) || 335 kW at 400 V AC 50/60 Hz (AC-3e) || 355 kW at 415 V AC 50/60 Hz (AC-3e) || 375 kW at 440 V AC 50/60 Hz (AC-3e) || 425 kW at 500 V AC 50/60 Hz (AC-3e) || 560 kW at 690 V AC 50/60 Hz (AC-3e) || 450 kW at 1000 V
Halogen Content Performance:
Halogen free plastic parts product
Safety Reliability Level:
B10d = 100000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 1800000 cycles contactor with mechanical load EN/ISO 13849-1
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Color:
dark grey
Pvc Free:
Yes
Mercury Free:
Yes
Device Short Name:
LC1G
Hold-In Power Consumption In Va:
17.0-17.0 VA
Circularity Profile:
ENVEOLI2105013
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Weight:
17.3 kg
Eu Rohs Directive:
Compliant with Exemptions
[Ie] Rated Operational Current:
1050 A (at <40°C) at <= 1000 V AC-1 || 800 A (at <60°C) at <= 440 V AC-3
Contactor Application:
power switching || motor control
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Compatibility Code:
LC1G
Auxiliary Contact Composition:
1 NO + 1 NC
Coil Technology:
built-in bidirectional peak limiting
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Range Of Product:
TeSys Giga
Power Dissipation Per Pole:
70 W AC-1 - Ith 1050 A || 42 W AC-3 - Ith 800 A
[Icw] Rated Short-Time Withstand Current:
5.5 kA - 10 s || 4.6 kA - 30 s || 3.6 kA - 1 min || 2.6 kA - 3 min || 1.7 kA - 10 min
Associated Fuse Rating:
800 A aM at <= 440 V for motor || 630 A aM at <= 690 V for motor || 1250 A gG at <= 690 V
Inrush Power In Va:
670-670 VA
Environmental Disclosure:
ENVPEP2105013
Operating Time:
40...70 ms closing || 15...50 ms opening
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Average Impedance:
0.000065 Ohm
Mounting Support:
plate
Product Or Component Type:
contactor
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
[Ui] Rated Insulation Voltage:
1000 V
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Inrush Power In W:
390 W
Ambient Air Temperature For Operation:
-25-60°C
Tightening Torque:
58 N.m
China Rohs Regulation:
X
Rated Breaking Capacity:
5870 A at 440 V
Sustainable Offer Status:
Green Premium product
$4,950.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 800A 450kW@440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 324mm x 210mm x 248mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose