- [Uc] Control Circuit Voltage:
- 110 V AC 50/60 Hz
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Sustainable Offer Status:
- Green Premium product
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
- Connections - Terminals:
- solder pins 0.035 mm)
- Weight:
- 0.18 kg
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Non Overlap Distance:
- 0.5 mm
- Ambient Air Temperature For Storage:
- -50-80°C
- Maximum Operating Rate:
- 3600 cyc/h
- Irms Rated Making Capacity:
- 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Environmental Disclosure:
- ENVPEP1503003EN
- Ip Degree Of Protection:
- IP2X VDE 0106
- Toxic Heavy Metal Free:
- Yes
- Country of Origin:
- Indonesia
- Utilisation Category:
- AC-3 || AC-3e || AC-4
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Sustainable Packaging:
- Yes
- [Ie] Rated Operational Current:
- 6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- [Icw] Rated Short-Time Withstand Current:
- 90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
- Control Circuit Type:
- AC 50/60 Hz
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Rated Breaking Capacity:
- 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
- Mechanical Robustness:
- shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
- Product Or Component Type:
- contactor
- Mechanical Durability:
- 10 Mcycles
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Poles Description:
- 3P
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Device Application:
- control
- Net Weight:
- 0.18 kg
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Reach Free Of Svhc:
- Yes
- Width:
- 45 mm
- Rohs Exemption Information:
- Yes
- Circularity Profile:
- ENVEOLI1503003EN
- Pole Contact Composition:
- 3 NO
- Auxiliary Contacts Type:
- instantaneous 1 NC
- Electrical Durability:
- 1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
- Motor Power Kw:
- 1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
- Warranty: