Schneider Electric LC1K0610F7TQ contactor TeSys K, 3P, AC-3/AC-3e,, 440V 6A, coil 110V AC

(No reviews yet) Write a Review
SKU:
LC1K0610F7TQ
MPN:
LC1K0610F7TQ
Condition:
New
Control Circuit Type:
AC 50/60 Hz standard
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Mechanical Durability:
10 Mcycles
Device Short Name:
LC1K
Mounting Support:
rail || plate
Pole Contact Composition:
3 NO
Poles Description:
3P
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Product Or Component Type:
contactor
Inrush Power In Va:
30-30 VA (at 20°C)
Associated Fuse Rating:
10 A gG for control circuit conforming to IEC 60947 || 10 A gG for control circuit conforming to VDE 0660 || 25 A gG at <= 440 V for power circuit
Mercury Free:
Yes
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc at 50/60 Hz (at <50°C) || drop-out: >= 0.20 Uc at 50/60 Hz (at <50°C)
Utilisation Category:
AC-3 || AC-3e || AC-4
Minimum Switching Voltage:
17 V for control circuit
Fire Resistance:
850°C IEC 60695-2-1
Insulation Resistance:
> 10 MOhm for control circuit
Warranty:
18 months
Maximum Operating Rate:
3600 cyc/h
Motor Power Kw:
1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
Minimum Switching Current:
5 mA for control circuit
Operating Altitude:
6561.68 ft (2000 m) without derating
Environmental Disclosure:
ENVPEP1503003EN
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Reach Free Of Svhc:
Yes
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Weight:
0.18 kg
Country of Origin:
France
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Net Weight:
0.18 kg
[Ui] Rated Insulation Voltage:
control circuit 690 V BS 5424 || control circuit 690 V IEC 60947 || power circuit 690 V BS 5424 || power circuit 690 V IEC 60947 || power circuit 690 V NF C 20-040 || control circuit 750 V VDE 0110 group C || power circuit 750 V VDE 0110 group C || c
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Eu Rohs Directive:
Compliant
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Contactor Application:
motor control
Flame Retardance:
class C2 conforming to NF F 16-101 || class C2 conforming to NF F 16-102 || V1 conforming to UL 94
Depth:
57 mm
Reach Regulation:
Free of Substances of Very High Concern above the threshold
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Operating Time:
10...20 ms coil de-energisation and NO opening || 15...25 ms coil de-energisation and NC opening || 10...20 ms between energisation of coil and closing of NO contact || 5...15 ms coil energisation and NC opening
$57.00