Schneider Electric

Schneider Electric LC1K0610T7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 480VAC coil

(No reviews yet) Write a Review
SKU:
LC1K0610T7
MPN:
LC1K0610T7
Condition:
New
Ambient Air Temperature For Storage:
-50-80°C
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Heat Dissipation:
1.3-1.3 W
Warranty:
18 months
Mechanical Durability:
10 Mcycles
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Environmental Disclosure:
ENVPEP1503003EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ie] Rated Operational Current:
6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
[Uc] Control Circuit Voltage:
480 V AC 50/60 Hz
Auxiliary Contact Composition:
1 NO
Sustainable Offer Status:
Green Premium product
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Non Overlap Distance:
0.5 mm
Circularity Profile:
ENVEOLI1503003EN
Eu Rohs Directive:
Compliant
Minimum Switching Current:
5 mA for Signaling circuit
Product Or Component Type:
contactor
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Inrush Power In Va:
30-30 VA (at 20°C)
Device Short Name:
LC1K
Poles Description:
3P
Device Application:
control
Utilisation Category:
AC-3 || AC-3e || AC-4
Signaling Circuit Frequency:
<= 400 Hz
Mercury Free:
Yes
Reach Free Of Svhc:
Yes
Toxic Heavy Metal Free:
Yes
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Country of Origin:
France
Minimum Switching Voltage:
17 V for Signaling circuit
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Maximum Operating Rate:
3600 cyc/h
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Contactor Application:
motor control
Ip Degree Of Protection:
IP2X VDE 0106
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Sustainable Packaging:
Yes
Depth:
57 mm
Control Circuit Type:
AC 50/60 Hz
Pole Contact Composition:
3 NO
Auxiliary Contacts Type:
instantaneous 1 NO
$57.00