Schneider Electric

Schneider Electric LC1K090087M7 Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 220 to 230VAC coil

(No reviews yet) Write a Review
SKU:
LC1K090087M7
MPN:
LC1K090087M7
Condition:
New
Device Short Name:
LC1K
Mounting Support:
rail || plate
Range:
TeSys
Operating Altitude:
6561.68 ft (2000 m) without derating
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Rohs Exemption Information:
Yes
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Control Circuit Type:
AC 50/60 Hz
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Inrush Power In Va:
30-30 VA (at 20°C)
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Height:
58 mm
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
Overvoltage Category:
III
Pole Contact Composition:
2 NO + 2 NC
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Warranty:
18 months
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
Ip Degree Of Protection:
IP2X VDE 0106
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Heat Dissipation:
1.3-1.3 W
Circularity Profile:
ENVEOLI1503003EN
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Country of Origin:
France
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Depth:
57 mm
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Connections - Terminals:
Faston terminals 2 2.8 mm) || Faston terminals 1 6.35 mm)
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Device Application:
control
Signaling Circuit Frequency:
<= 400 Hz
Mechanical Durability:
10 Mcycles
Environmental Disclosure:
ENVPEP1503003EN
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Maximum Operating Rate:
3600 cyc/h
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Sustainable Packaging:
Yes
Ambient Air Temperature For Storage:
-50-80°C
Contactor Application:
resistive load
Poles Description:
4P
Product Or Component Type:
contactor
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
$81.00

Description

TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V 50/60Hz AC coil, without built-in auxiliary contact, connection by Faston connectors. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose