Schneider Electric

Schneider Electric LC1K090087N7 Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 400 to 415VAC coil

(No reviews yet) Write a Review
SKU:
LC1K090087N7
MPN:
LC1K090087N7
Condition:
New
Circularity Profile:
ENVEOLI1503003EN
Control Circuit Type:
AC 50/60 Hz
Net Weight:
0.18 kg
Heat Dissipation:
1.3-1.3 W
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Inrush Power In Va:
30-30 VA (at 20°C)
Ambient Air Temperature For Storage:
-50-80°C
Range:
TeSys
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Signaling Circuit Frequency:
<= 400 Hz
Reach Free Of Svhc:
Yes
Environmental Disclosure:
ENVPEP1503003EN
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Sustainable Offer Status:
Green Premium product
Pole Contact Composition:
2 NO + 2 NC
Maximum Operating Rate:
3600 cyc/h
Product Or Component Type:
contactor
Ip Degree Of Protection:
IP2X VDE 0106
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Connections - Terminals:
Faston terminals 2 2.8 mm) || Faston terminals 1 6.35 mm)
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Toxic Heavy Metal Free:
Yes
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application:
resistive load
Weight:
0.18 kg
Depth:
57 mm
Poles Description:
4P
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Rohs Exemption Information:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Height:
58 mm
Mercury Free:
Yes
Warranty:
18 months
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Sustainable Packaging:
Yes
Operating Altitude:
6561.68 ft (2000 m) without derating
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Device Application:
control
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive:
Compliant
Country of Origin:
France
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Utilisation Category:
AC-1
Width:
45 mm
$81.00