Schneider Electric

Schneider Electric LC1K09105E7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 48VAC coil

(No reviews yet) Write a Review
SKU:
LC1K09105E7
MPN:
LC1K09105E7
Condition:
New
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Circularity Profile:
ENVEOLI1503003EN
Contactor Application:
motor control || resistive load
Warranty:
18 months
Overvoltage Category:
III
Mechanical Durability:
10 Mcycles
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Reach Free Of Svhc:
Yes
[Uc] Control Circuit Voltage:
48 V AC 50/60 Hz
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Heat Dissipation:
1.3-1.3 W
Inrush Power In Va:
30-30 VA (at 20°C)
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Rohs Exemption Information:
Yes
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Range:
TeSys
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Product Or Component Type:
contactor
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Control Circuit Type:
AC 50/60 Hz
Pole Contact Composition:
3 NO
Minimum Switching Voltage:
17 V for Signaling circuit
Signaling Circuit Frequency:
<= 400 Hz
Auxiliary Contact Composition:
1 NO
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Connections - Terminals:
solder pins 0.035 mm)
Toxic Heavy Metal Free:
Yes
Eu Rohs Directive:
Compliant
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Environmental Disclosure:
ENVPEP1503003EN
Reach Regulation:
Free of Substances of Very High Concern above the threshold
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Operating Altitude:
6561.68 ft (2000 m) without derating
Sustainable Offer Status:
Green Premium product
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
Auxiliary Contacts Type:
instantaneous 1 NO
Minimum Switching Current:
5 mA for Signaling circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Maximum Operating Rate:
3600 cyc/h
Country of Origin:
Indonesia
Non Overlap Distance:
0.5 mm
$75.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 48V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by solder pins for printed circuit boards. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose