Schneider Electric

Schneider Electric LC1K0910D7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 42VAC coil

(No reviews yet) Write a Review
SKU:
LC1K0910D7
MPN:
LC1K0910D7
Condition:
New
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Voltage:
17 V for Signaling circuit
Rohs Exemption Information:
Yes
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Device Short Name:
LC1K
Sustainable Offer Status:
Green Premium product
Non Overlap Distance:
0.5 mm
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Signaling Circuit Frequency:
<= 400 Hz
Overvoltage Category:
III
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Circularity Profile:
ENVEOLI1503003EN
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Uc] Control Circuit Voltage:
42 V AC 50/60 Hz
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Product Or Component Type:
contactor
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Minimum Switching Current:
5 mA for Signaling circuit
Country of Origin:
France
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Poles Description:
3P
Heat Dissipation:
1.3-1.3 W
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Range:
TeSys
Motor Power Kw:
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Auxiliary Contact Composition:
1 NO
Pole Contact Composition:
3 NO
Depth:
57 mm
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
Operating Altitude:
6561.68 ft (2000 m) without derating
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Sustainable Packaging:
Yes
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Ie] Rated Operational Current:
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Maximum Operating Rate:
3600 cyc/h
Environmental Disclosure:
ENVPEP1503003EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Auxiliary Contacts Type:
instantaneous 1 NO
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
$75.00