- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Rohs Exemption Information:
- Yes
- Electrical Durability:
- 1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
- Device Short Name:
- LC1K
- Sustainable Offer Status:
- Green Premium product
- Non Overlap Distance:
- 0.5 mm
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Signaling Circuit Frequency:
- <= 400 Hz
- Overvoltage Category:
- III
- Hold-In Power Consumption In Va:
- 4.5-4.5 VA (at 20°C)
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Circularity Profile:
- ENVEOLI1503003EN
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- [Uc] Control Circuit Voltage:
- 42 V AC 50/60 Hz
- Irms Rated Making Capacity:
- 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Product Or Component Type:
- contactor
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Country of Origin:
- France
- Control Circuit Voltage Limits:
- operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
- Poles Description:
- 3P
- Heat Dissipation:
- 1.3-1.3 W
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Range:
- TeSys
- Motor Power Kw:
- 2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Auxiliary Contact Composition:
- 1 NO
- Pole Contact Composition:
- 3 NO
- Depth:
- 57 mm
- Connections - Terminals:
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
- Mercury Free:
- Yes
- Eu Rohs Directive:
- Compliant
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Sustainable Packaging:
- Yes
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- [Ie] Rated Operational Current:
- 9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Maximum Operating Rate:
- 3600 cyc/h
- Environmental Disclosure:
- ENVPEP1503003EN
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Auxiliary Contacts Type:
- instantaneous 1 NO
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz