Schneider Electric

Schneider Electric LC1K0910L7 IEC contactor, TeSys K, nonreversing, 9A, 5HP at 480VAC, 3 phase, 1 NO auxiliary, 200/208VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1K0910L7
MPN:
LC1K0910L7
Condition:
New
Eu Rohs Directive:
Compliant
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Environmental Disclosure:
ENVPEP1503003EN
Minimum Switching Current:
5 mA for Signaling circuit
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Reach Free Of Svhc:
Yes
Toxic Heavy Metal Free:
Yes
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Sustainable Packaging:
Yes
Inrush Power In Va:
30-30 VA (at 20°C)
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Motor Power Kw:
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/
Poles Description:
3P
Range:
TeSys
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Signaling Circuit Frequency:
<= 400 Hz
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Product Or Component Type:
contactor
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Contactor Application:
motor control || resistive load
Maximum Operating Rate:
3600 cyc/h
Mechanical Durability:
10 Mcycles
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Pole Contact Composition:
3 NO
Country of Origin:
Indonesia
[Ie] Rated Operational Current:
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Control Circuit Type:
AC 50/60 Hz
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Minimum Switching Voltage:
17 V for Signaling circuit
Operating Altitude:
6561.68 ft (2000 m) without derating
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Circularity Profile:
ENVEOLI1503003EN
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Auxiliary Contacts Type:
instantaneous 1 NO
Warranty:
18 months
$75.00

Description

TeSys K IEC motor control contactors are used in industrial control applications. This Type K IEC nonreversing contactor has 3 normally open contacts. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 2HP at 200 to 208VAC, 3HP at 240VAC, 5HP at 480VAC and 5HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 1.5HP at 240VAC single phase. The IEC contactor has a 200/208 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. Contactor is supplied with one normally open auxiliary contact. The contactor is 2.28 inches tall, 1.77 inches wide and 2.24 inches deep. It weighs 0.40 lbs. This IEC contactor is UL Listed and CSA certified.
View AllClose