- [Ie] Rated Operational Current:
- 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Contactor Application:
- resistive load
- Product Or Component Type:
- contactor
- Heat Dissipation:
- 1.3-1.3 W
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Sustainable Packaging:
- Yes
- [Uc] Control Circuit Voltage:
- 230 V AC 50/60 Hz
- Mechanical Robustness:
- shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
- Circularity Profile:
- ENVEOLI1503003EN
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Utilisation Category:
- AC-1
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Control Circuit Voltage Limits:
- operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
- [Icw] Rated Short-Time Withstand Current:
- 115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
- Eu Rohs Directive:
- Compliant
- Maximum Operating Rate:
- 3600 cyc/h
- Depth:
- 57 mm
- Pole Contact Composition:
- 4 NO
- Sustainable Offer Status:
- Green Premium product
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Mercury Free:
- Yes
- Control Circuit Type:
- AC 50/60 Hz
- Signaling Circuit Frequency:
- <= 400 Hz
- Connections - Terminals:
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
- Poles Description:
- 4P
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Irms Rated Making Capacity:
- 144 A AC for power circuit conforming to IEC 60947
- Environmental Disclosure:
- ENVPEP1503003EN
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Inrush Power In Va:
- 30-30 VA (at 20°C)
- Height:
- 58 mm
- Reach Free Of Svhc:
- Yes
- Electrical Durability:
- 0.3 Mcycles 20 A AC-1 <= 690 V
- Warranty:
- 18 months
- Toxic Heavy Metal Free:
- Yes
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
- Range:
- TeSys
- Overvoltage Category:
- III
- Hold-In Power Consumption In Va:
- 4.5-4.5 VA (at 20°C)
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Device Application:
- control
- Mechanical Durability:
- 10 Mcycles