Schneider Electric LC1K1210N7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NO aux., 400 to 415VAC coil
Schneider Electric
$86.00
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NO aux., 400 to 415VAC coil
- Mounting Support:
- plate || rail
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Mechanical Durability:
- 10 Mcycles
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
- Irms Rated Making Capacity:
- 144 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Control Circuit Type:
- AC 50/60 Hz
- Eu Rohs Directive:
- Compliant
- Heat Dissipation:
- 1.3-1.3 W
- Rated Breaking Capacity:
- 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Control Circuit Voltage Limits:
- operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
- Utilisation Category:
- AC-3 || AC-3e || AC-1 || AC-4
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
- Mechanical Robustness:
- shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
- [Icw] Rated Short-Time Withstand Current:
- 115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
- Ambient Air Temperature For Storage:
- -50-80°C
- Weight:
- 0.18 kg
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Inrush Power In Va:
- 30-30 VA (at 20°C)
- Pole Contact Composition:
- 3 NO
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Overvoltage Category:
- III
- Motor Power Kw:
- 3 kW 220...230 V AC 50/60 Hz AC-3 || 5.5 kW 380...415 V AC 50/60 Hz AC-3 || 5.5 kW 440 V AC 50/60 Hz AC-3 || 4 kW 690 V AC 50/60 Hz AC-3 || 3 kW 220...230 V AC 50/60 Hz AC-3e || 5.5 kW 380...415 V AC 50/60 Hz AC-3e || 5.5 kW 440 V AC 50/60 Hz AC-3e |
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Auxiliary Contacts Type:
- instantaneous 1 NO
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Contactor Application:
- resistive load || motor control
- Warranty:
- 18 months
- Product Or Component Type:
- contactor
- Auxiliary Contact Composition:
- 1 NO
- Tightening Torque:
- 0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
- [Uc] Control Circuit Voltage:
- 400...415 V AC 50/60 Hz
- Mercury Free:
- Yes
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Reach Free Of Svhc:
- Yes
- Non Overlap Distance:
- 0.5 mm
- Net Weight:
- 0.18 kg
- Maximum Operating Rate:
- 3600 cyc/h
- Electrical Durability:
- 1.3 Mcycles 12 A AC-3 <= 440 V || 1.3 Mcycles 12 A AC-3e <= 440 V || 0.3 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 72 A AC-4 <= 440 V
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
- [Ie] Rated Operational Current:
- 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV