Schneider Electric

Schneider Electric LC1K16106M7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 16A, 1 NO aux., 220 to 230VAC coil

(No reviews yet) Write a Review
SKU:
LC1K16106M7
MPN:
LC1K16106M7
Condition:
New
Height:
58 mm
Reach Free Of Svhc:
Yes
Sustainable Offer Status:
Green Premium product
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
[Uc] Control Circuit Voltage:
220...230 V AC 50/60 Hz
Pole Contact Composition:
3 NO
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Electrical Durability:
1.3 Mcycles 16 A AC-3 <= 440 V || 1.3 Mcycles 16 A AC-3e <= 440 V
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Toxic Heavy Metal Free:
Yes
Signaling Circuit Frequency:
<= 400 Hz
Minimum Switching Voltage:
17 V for Signaling circuit
Overvoltage Category:
III
Width:
45 mm
Mechanical Durability:
10 Mcycles
Country of Origin:
France
Inrush Power In Va:
30-30 VA (at 20°C)
Auxiliary Contact Composition:
1 NO
Flame Retardance:
V1 conforming to UL 94
Rated Breaking Capacity:
110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Motor Power Kw:
4 kW 220...230 V AC 50/60 Hz AC-3 || 7.5 kW 380...415 V AC 50/60 Hz AC-3 || 5.5 kW 440 V AC 50/60 Hz AC-3 || 4 kW 690 V AC 50/60 Hz AC-3 || 4 kW 220...230 V AC 50/60 Hz AC-3e || 7.5 kW 380...415 V AC 50/60 Hz AC-3e || 5.5 kW 440 V AC 50/60 Hz AC-3e |
Weight:
0.18 kg
Ambient Air Temperature For Storage:
-50-80°C
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Utilisation Category:
AC-3 || AC-3e
Operating Altitude:
6561.68 ft (2000 m) without derating
Heat Dissipation:
1.3-1.3 W
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Connections - Terminals:
lugs-ring terminals 7 mm)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Depth:
57 mm
Irms Rated Making Capacity:
160 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Warranty:
18 months
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Icw] Rated Short-Time Withstand Current:
115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
Auxiliary Contacts Type:
instantaneous 1 NO
Ip Degree Of Protection:
IP2X VDE 0106
Mounting Support:
plate || rail
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Product Or Component Type:
contactor
[Ie] Rated Operational Current:
16 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 16 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Tightening Torque:
0.8-1.3 N.m lugs-ring terminals Philips No 2 || 0.8-1.3 N.m lugs-ring terminals flat Ø 6 mm || 0.8-1.3 N.m lugs-ring terminals pozidriv No 2
Circularity Profile:
ENVEOLI1503003EN
Maximum Operating Rate:
3600 cyc/h
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Poles Description:
3P
$172.00