Schneider Electric

Schneider Electric LC1K1610F7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 16A, 1 NO aux., 110VAC coil

(No reviews yet) Write a Review
SKU:
LC1K1610F7
MPN:
LC1K1610F7
Condition:
New
Flame Retardance:
V1 conforming to UL 94
Non Overlap Distance:
0.5 mm
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Ambient Air Temperature For Operation:
-25-50°C
Circularity Profile:
ENVEOLI1503003EN
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Depth:
57 mm
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Pole Contact Composition:
3 NO
Insulation Resistance:
> 10 MOhm for Signaling circuit
Sustainable Packaging:
Yes
Sustainable Offer Status:
Green Premium product
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Reach Free Of Svhc:
Yes
Maximum Operating Rate:
3600 cyc/h
Device Short Name:
LC1K
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
Net Weight:
0.18 kg
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contact Composition:
1 NO
[Uc] Control Circuit Voltage:
110 V AC 50/60 Hz
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Poles Description:
3P
Utilisation Category:
AC-3 || AC-3e
Heat Dissipation:
1.3-1.3 W
Rated Breaking Capacity:
110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Mercury Free:
Yes
Minimum Switching Current:
5 mA for Signaling circuit
Motor Power Kw:
4 kW 220...230 V AC 50/60 Hz AC-3 || 7.5 kW 380...415 V AC 50/60 Hz AC-3 || 5.5 kW 440 V AC 50/60 Hz AC-3 || 4 kW 690 V AC 50/60 Hz AC-3 || 4 kW 220...230 V AC 50/60 Hz AC-3e || 7.5 kW 380...415 V AC 50/60 Hz AC-3e || 5.5 kW 440 V AC 50/60 Hz AC-3e |
[Ie] Rated Operational Current:
16 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 16 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Ip Degree Of Protection:
IP2X VDE 0106
Range:
TeSys
Rohs Exemption Information:
Yes
Signaling Circuit Frequency:
<= 400 Hz
Mounting Support:
rail || plate
Overvoltage Category:
III
Irms Rated Making Capacity:
160 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Product Or Component Type:
contactor
Warranty:
18 months
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Country of Origin:
Indonesia
$172.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 16A/690V AC-3 (7.5kW@400V). It provides a 110V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose