Schneider Electric LC1K1610P7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 16A, 1 NO aux., 230VAC coil
Schneider Electric
$172.00
TeSys K contactor, 3 poles (3NO), for motor control applications up to 16A/690V AC-3 (7.5kW@400V). It provides a 230V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
- Electrical Durability:
- 1.3 Mcycles 16 A AC-3 <= 440 V || 1.3 Mcycles 16 A AC-3e <= 440 V
- Control Circuit Voltage Limits:
- operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Device Application:
- control
- Reach Free Of Svhc:
- Yes
- Ip Degree Of Protection:
- IP2X VDE 0106
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
- Sustainable Offer Status:
- Green Premium product
- Device Short Name:
- LC1K
- Range:
- TeSys
- Non Overlap Distance:
- 0.5 mm
- Overvoltage Category:
- III
- Environmental Disclosure:
- ENVPEP1503003EN
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
- Ambient Air Temperature For Storage:
- -50-80°C
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
- Utilisation Category:
- AC-3 || AC-3e
- Rohs Exemption Information:
- Yes
- Signaling Circuit Frequency:
- <= 400 Hz
- Auxiliary Contacts Type:
- instantaneous 1 NO
- Contactor Application:
- motor control
- Mounting Support:
- plate || rail
- [Icw] Rated Short-Time Withstand Current:
- 115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
- Sustainable Packaging:
- Yes
- Inrush Power In Va:
- 30-30 VA (at 20°C)
- Ambient Air Temperature For Operation:
- -25-50°C
- Auxiliary Contact Composition:
- 1 NO
- Tightening Torque:
- 0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
- Warranty:
- 18 months
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Country of Origin:
- France
- Maximum Operating Rate:
- 3600 cyc/h
- Hold-In Power Consumption In Va:
- 4.5-4.5 VA (at 20°C)
- Irms Rated Making Capacity:
- 160 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Flame Retardance:
- V1 conforming to UL 94
- Mechanical Robustness:
- shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Width:
- 45 mm
- [Ie] Rated Operational Current:
- 16 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 16 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Mechanical Durability:
- 10 Mcycles
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Pole Contact Composition:
- 3 NO
- [Uc] Control Circuit Voltage:
- 230 V AC 50/60 Hz
- Net Weight:
- 0.18 kg
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit