- Associated Fuse Rating:
- 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- [Uc] Control Circuit Voltage:
- 24 V DC
- Range:
- TeSys || TeSys Deca
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Inrush Power In W:
- 5.4-5.4 W 20°C)
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
- Net Weight:
- 1.017 kg
- Device Short Name:
- LC2D
- Tightening Torque:
- control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals flat Ø 8 mm M3.5 || power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3
- Depth:
- 95 mm
- Operating Time:
- 53.55...72.45 ms closing || 16...24 ms opening
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Poles Description:
- 3P
- Interlocking Type:
- mechanical
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Country of Origin:
- Indonesia
- Pole Contact Composition:
- 3 NO
- [Ie] Rated Operational Current:
- 9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Fire Resistance:
- 850°C IEC 60695-2-1
- Device Presentation:
- preassembled with reversing power busbar
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Product Certifications:
- DNV || CSA || CCC || UL || GL || LROS (Lloyds register of shipping) || BV || RINA || GOST || UKCA
- Hold-In Power Consumption In W:
- 5.4-5.4 W 20°C
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- Warranty:
- 18 months
- Control Circuit Voltage Limits:
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Overvoltage Category:
- III
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- [Icw] Rated Short-Time Withstand Current:
- 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Mercury Free:
- Yes
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Contactor Application:
- resistive load || motor control
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Product Name:
- TeSys D || TeSys Deca
- Protective Cover:
- with
- Signaling Circuit Frequency:
- 25...400 Hz
- Pvc Free:
- Yes
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D