Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Overvoltage Category:
III
Device Presentation:
preassembled with reversing power busbar
Interlocking Type:
electrical and mechanical
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Eu Rohs Directive:
Compliant with Exemptions
Circularity Profile:
ENVEOLI1102030EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Horse Power Rating:
1 hp at 115 V AC 60 Hz for 1 phase motors || 2 hp at 230/240 V AC 60 Hz for 1 phase motors || 3 hp at 200/208 V AC 60 Hz for 3 phase motors || 3 hp at 230/240 V AC 60 Hz for 3 phase motors || 7.5 hp at 460/480 V AC 60 Hz for 3 phase motors || 10 hp a
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.8...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Contactor Application:
resistive load || motor control
Power Dissipation Per Pole:
1.56 W AC-1 || 0.36 W AC-3 || 0.36 W AC-3e
Mechanical Durability:
30 Mcycles
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Minimum Switching Current:
5 mA for Signaling circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Minimum Switching Voltage:
17 V for Signaling circuit
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Inrush Power In W:
2.4-2.4 W 20°C)
Product Name:
TeSys D || TeSys Deca
Pole Contact Composition:
3 NO
Time Constant:
40 ms
Ambient Air Temperature For Storage:
-60-80°C
Hold-In Power Consumption In W:
2.4-2.4 W 20°C
Sustainable Offer Status:
Green Premium product
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Depth:
95 mm
Fire Resistance:
850°C IEC 60695-2-1
Rohs Exemption Information:
Yes
Operating Time:
65.45...88.55 ms closing || 20...30 ms opening
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Control Circuit Type:
DC low consumption
Weight:
1.027 kg
Product Certifications:
DNV || CSA || CCC || UL || GL || LROS (Lloyds register of shipping) || BV || RINA || GOST || UKCA
Mercury Free:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
Device Short Name:
LC2D
Pollution Degree:
3
Utilisation Category:
AC-3 || AC-1 || AC-3e
Operating Altitude:
0...9842.52 ft (0...3000 m)
Mounting Support:
rail || plate
Poles Description:
3P
Coil Technology:
built-in bidirectional peak limiting diode suppressor
$462.00

Description

TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V). It provides low consumption 24V DC coils with transient suppressor module, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).